Navigation

  • Page 1

    CNC SYSTEMOSP-E100MOSP-E10MALARM & ERROR LIST(4th Edition)Pub No. 4293-E-R2 (ME37-005-R4) Oct. 2000

  • Page 2

    4293-E P-(i)SAFETY PRECAUTIONSSAFETY PRECAUTIONSEeoemalpl001The machine is equipped with safety devices which serve to protect personnel and the machineitself from hazards arising from unforeseen accidents. However, operators must not rely exclusivelyon these safety devices: they must also beco...

  • Page 3

    4293-E P-(ii)SAFETY PRECAUTIONS(3) When turning on the power, turn on the main power disconnect switch first, then the CONTROLON switch on the operation panel.3.Precautions Relating To OperationEeoemalpl004(1) After turning on the power, carry out inspection and adjustment in accordance with the ...

  • Page 4

    4293-E P-(iii)SAFETY PRECAUTIONS6.Precautions During Maintenance Inspection and When Trouble OccursEeoemalpl007In order to prevent unforeseen accidents, damage to the machine, etc., it is essential to observe thefollowing points when performing maintenance inspections or during checking when trou...

  • Page 5

    4293-E P-(iv)SAFETY PRECAUTIONS• Is the external air inlet blocked?If it is blocked, clean it with compressed air.7.General PrecautionsEeoemalpl008(1) Keep the vicinity of the machine clean and tidy.(2) Wear appropriate clothing while working, and follow the instructions of someone with suffici...

  • Page 6

    4293-E P-(i)INTRODUCTIONINTRODUCTIONEeoemalan001Before using this NC unit, read this manual thoroughly in order to ensure correct use.This manual explains how to use and maintain the control so that it will deliver its full performanceand maintain accuracy over the long term.You must pay particul...

  • Page 7

    4293-E P-(i) TABLE OF CONTENTSactionGoToR:TABLE OF CONTENTS 8,CLASSIFICATION 8, OF ALARMS 8,....................................................................1 15,CPU 15, ALARM ...... 15,.............................................................................................8 24,ALARM ...

  • Page 8

    4293-E P-1SECTION 1 CLASSIFICATION OF ALARMSSECTION 1 CLASSIFICATION OF ALARMSEeoemalge001Alarms related with the OSP are classified into six types such as CPU alarm, Alarm P, A, B, C andD.1.Alarm ClassificationsEeoemalge002AlarmMachine Conditions When ALARM Lamp Comes ONOperative NC Functions ...

  • Page 9

    4293-E P-2SECTION 1 CLASSIFICATION OF ALARMSThe display format of CPU alarm, alarm P, A, B, C and D is indicated on pages 2 and 4.EIOEMALGE001r01SPECIAL STATUS WORD = 0165ACCESS ADDRESS = 00104250D0=43520000D1=00000000D2=0000000BD3=00000210(Indicates the data reg-ister D0 through D7.)D4=0000000...

  • Page 10

    4293-E P-3SECTION 1 CLASSIFICATION OF ALARMSEIOEMALGE002R01Display Format of CPU Alarms (Address error)23.CPU alarm Illegal instruction error15.CPU alarm User interrupt error4.CPU alarm Zero divide error16.CPU alarm Coprocessor protocol error5.CPU alarm CHK instruction error17.CPU alarm Format ...

  • Page 11

    4293-E P-4SECTION 1 CLASSIFICATION OF ALARMSDepending on the alarm content, the following display is given.EIOEMALGE003R01EIOEMALGE004r01SPECIAL STATUS WORD = C005 ACCESS ADDRESS = 00025041D0=43520000D1=00000000D2=00000000D3=00000210(Indicates the data reg-ister D0 through D7.)D4=0000000AD5=000...

  • Page 12

    4293-E P-5SECTION 1 CLASSIFICATION OF ALARMS2.Object Number and Object MessageEeoemalge003The object number and the object message show the programming system and the control axiswhere the alarm has occurred by the number and message as shown in the table blow:As indicated above, the object num...

  • Page 13

    4293-E P-6SECTION 1 CLASSIFICATION OF ALARMS2-1.Alarm CodesEeoemalge004In this manual, alarm codes are explained using such as "X", "XX", and "XXYY".Explanation is given in the following methods:(1) The alarm code indicated in this text can be used directly as the ...

  • Page 14

    4293-E P-7SECTION 1 CLASSIFICATION OF ALARMS2-3.How to check alarm contentsEeoemalge006The method to find the details of the alarm indicated by the bit pattern is explained below using anexample.EIOEMALGE005r01Error Display FormatError numberError messageIndication of ERRORError codeError chara...

  • Page 15

    4293-E P-8SECTION 2 CPU ALARMSECTION 2CPU ALARM0001 BUS ERROR .................................................................................................. 90002 ADDRESS ...................................................................................................... 90003 ILLEGAL INS...

  • Page 16

    4293-E P-9SECTION 2 CPU ALARM0001 BUS ERROREeoemale1001This alarm is caused when the bus error exception has occurred with the CPU.Details of BUS error:When the bus error occurs, the CPU status is displayed in hexadecimal numbers.At the same time, the red LED at the CPU rack lights up.The bus e...

  • Page 17

    4293-E P-10SECTION 2 CPU ALARM0003 ILLEGAL INSTRUCTIONEeoemale1003This error occurs when the CPU has read an unallowable instruction.[Index]None[Character-string]None[Code]None[Probable Faulty Locations]Main board[Measures to Take]Replace the main board.0004 ZERO DIVIDEEeoemale1004This error oc...

  • Page 18

    4293-E P-11SECTION 2 CPU ALARM[Measures to Take]Replace the main board.0007 PRIVILEGE VIOLATIONEeoemale1007This error occurs when the CPU executes a privilege instruction (instructions that can be executed only in the supervisor condi-tion) in the user condition.[Index]None[Character-string]Non...

  • Page 19

    4293-E P-12SECTION 2 CPU ALARM[Probable Faulty Locations]Main board[Measures to Take]Replace the main board.0011 EXCEPTION VECTOREeoemale1011This error occurs when the CPU has referenced the exception vector which is not referenced normally.[Index]None[Character-string]None[Code]None[Probable F...

  • Page 20

    4293-E P-13SECTION 2 CPU ALARM0014 TRAP INSTRUCTIONEeoemale1014This error occurs when the CPU has referenced the TRAP exception vector which is not referenced normally.[Index]None[Character-string]None[Code]None[Probable Faulty Locations]Main board[Measures to Take]Replace the main board.0015 U...

  • Page 21

    4293-E P-14SECTION 2 CPU ALARMReplaces the main board0018 UNINITIALIZED INTERRUPTEeoemale1018This error occurs when an interruption occurs before initialization of the vector numbers of peripheral devices.[Index]None[Character-string]None[Code]None[Probable Faulty Locations]Main board[Measures ...

  • Page 22

    4293-E P-15SECTION 2 CPU ALARMMain board[Measures to Take]Replaces the main board0022 FPCP UNDERFLOWEeoemale1022This error occurs when the floating-point coprocessor obtains a value too small to express as a result of arithmetic operation. [Index]None[Character-string]None[Code]None[Probable Fa...

  • Page 23

    4293-E P-16SECTION 2 CPU ALARMNone[Probable Faulty Locations]Main board[Measures to Take]Replaces the main board

  • Page 24

    4293-E P-17SECTION 3 ALARM PSECTION 3ALARM P0800 Spindle D/A control data file read ................................................................. 220801 TCP/IP illegal ................................................................................................ 220802 Load information fi...

  • Page 25

    4293-E P-18SECTION 3 ALARM P0861 MCS Power unit version error ....................................................................... 390862 MCS Winding-change failed ......................................................................... 390863 MCS Encoder-link error ...........................

  • Page 26

    4293-E P-19SECTION 3 ALARM P0908 SVP DIFF over ............................................................................................. 530909 SVP servo amp ............................................................................................ 540910 SVP APA check data ..............

  • Page 27

    4293-E P-20SECTION 3 ALARM P0948 TFP Field net communication error .............................................................. 670949 IO DIAGNOSTICS data file read .................................................................. 670950 IO MACRO data file read .................................

  • Page 28

    4293-E P-21SECTION 3 ALARM P0991 TASK information table data unsuitable ....................................................... 790992 PLC backup data file read ............................................................................ 800993 TCP/IP board error ..................................

  • Page 29

    4293-E P-22SECTION 3 ALARM P0800 Spindle D/A control data file readEeoemale2001The NC failed to properly read the spindle D/A control data file. [Index]None[Character-string]None[Code]XYX=Gear set number (Initially found problem gear set number.If Y = any of 1 to 6, X will not be displayed.)Y =...

  • Page 30

    4293-E P-23SECTION 3 ALARM PProblem file name[Code]NoneHowever, there may be a case where an error message is output in the console line.[Probable Faulty Locations]Defective installation, software production error, or specification code error[Measures to Take]• Reinstall the software.• Reis...

  • Page 31

    4293-E P-24SECTION 3 ALARM P[Probable Faulty Locations]• If the alarm occurred during normal NC operation, the PBU file has been deleted or its data has been destroyed.• If the alarm occurred without NC operation after installation of control floppy disk, the PBU file type was wrong or no P...

  • Page 32

    4293-E P-25SECTION 3 ALARM P4...C-axis speed change ratio is set by a code.5...X-axis speed change ratio exceeds the setting range.6...Y-axis speed change ratio exceeds the setting range.7...Z-axis speed change ratio exceeds the setting range.8...C-axis speed change ratio exceeds the setting ra...

  • Page 33

    4293-E P-26SECTION 3 ALARM P bit6->FCP executed SNMI command. bit5->Oscillator module stopped oscillation. bit4->Always 0 bit3->Always 0 bit2->Always 0 bit1->Always 0 bit0->Always 00810 NCIO data file readEeoemale2011The NC failed to read I/O data file.[Index]None[Character...

  • Page 34

    4293-E P-27SECTION 3 ALARM P[Measures to Take]Consult the machine maker.0812 MCS startEeoemale2013An error occurred in initialization of MCS when the power was supplied.[Index]None or axis name[Character-string]Varies with the code.[Code]XXXXYYYYXXXX: Kind of generated alarmYYYY: Further inform...

  • Page 35

    4293-E P-28SECTION 3 ALARM PD001...In buffering the initial data in AT (auto) receive mode, the software synchronization bit does not come on within 3 sec-onds.YYYY is always 0.D002...In buffering the initial data in AT (auto) receive mode, the buffer A received a wrong format code.Two low-orde...

  • Page 36

    4293-E P-29SECTION 3 ALARM P3...The received data size is 2 bytes or less.YYYY: always 04...Data is received from a station other than the slave station that sent the date.YYYY: information of the received frame5...The NC received the data that the NC had transmitted in a way other than broadca...

  • Page 37

    4293-E P-30SECTION 3 ALARM P[Index][Character-string][axis name] [device name] [file name] [character-string] or none[Code]XYZZAAAAX: Axis kind; Y: Rough classification; ZZ: Minuteclassification; AAAA: DataX:1= NC-controlled axis 2= spindle 3= PLC-controlled axisY:0= Error in reading servo da...

  • Page 38

    4293-E P-31SECTION 3 ALARM P[Character-string]AAAABBAAAA-> Task name being processed when the loop error was detected.BB-> Program module number being executed (hexadecimal)[Code]XXXXXXXX-> Program counter value (hexadecimal) at the time of error detection[Probable Faulty Locations]•...

  • Page 39

    4293-E P-32SECTION 3 ALARM PXX=1:Synchronous counter value remains 1.X=2:A system alarm occurred when the synchronous counter value was 1.X=3:Synchronous counter value remains 3.X=4:A system alarm occurred when the synchronous counter value was 3.[Probable Faulty Locations]1 ADP(AD conversion p...

  • Page 40

    4293-E P-33SECTION 3 ALARM P[Probable Faulty Locations]• Faulty SPMC• Faulty SUPER MAIN BOARD(SPMB)• Faulty software0832 SPM System Call errorEeoemale2023In the system call processing with the SUPER MAIN CARD(SPMC), error was detected.[Code]2XXXXXXXXXXXXXX: Error code which was returned f...

  • Page 41

    4293-E P-34SECTION 3 ALARM P0835 MCS CommunicationEeoemale2026An error occurred during shake-hand communication with MCS.[Index]Axis name or none[Character-string]Shake-hand communication error number (2 digits), error data (8 digits), and [command name]-[channel number]-netaddress (controller ...

  • Page 42

    4293-E P-35SECTION 3 ALARM P"#20"-> INT loop error"#21"-> INT5 loop error"#22"-> INT4 loop error"#23"-> INT3 loop error"#24"-> INT2 loop error"#25"-> INT1 loop error"#26"-> Access denied"#27"-&g...

  • Page 43

    4293-E P-36SECTION 3 ALARM P1...Speed command (8408)2...Laser linear scale value (4413)3...Backlash (4406)4...Actual position without positioning error compensation (440A)5...Positioning error compensation amount6...Full-closed loop encoder value (4410)7...Semi-closed loop encoder value (4411)8...

  • Page 44

    4293-E P-37SECTION 3 ALARM P X(alarm No.):2 1:+5V abnormal voltage 2:+12V abnormal voltage 3:-12V abnormal voltage X(alarm No.):3 1:Converter over current 2:Abnormal power element 3:Converter short circut 4:Abnormal regenerative circuit(type in power regenerative circuit) 5:Abnormal reg...

  • Page 45

    4293-E P-38SECTION 3 ALARM P• Instantaneous power interruption0857 MCS Motor over currentEeoemale2035The invertor unit has detected excessive current flowing in the motor cable.[Index]Axis name or none (spindle)[Character-string]None[Code]XXXXYYYYXXXX= U-phase current detected when this alarm...

  • Page 46

    4293-E P-39SECTION 3 ALARM P[Probable Faulty Locations]• Power unit• Power cables or connectors• Instantaneous power interruption0861 MCS Power unit version errorEeoemale2039The invertor unit allowable current is smaller than the current limit specified in the servo data file.[Index]Axis ...

  • Page 47

    4293-E P-40SECTION 3 ALARM Pbit 11 1: Transmission loop error in AT (auto) modebit 10 1: Data over error in data receiving part of interfacebit 9 1: Undefinedbit 8 1: Undefinedbit 7 1: Undefinedbit 6 1: Modulation code errorbit 5 1: CRC errorbit 4 1: Format errorbit 3 1: Double ...

  • Page 48

    4293-E P-41SECTION 3 ALARM PIf YY=0, the encoder link error status C2ERR at the time of error detection appears.If YY=1, 2, or 3, the transferred frame information QC2MTINF appears.If YY=4, the network address of the responding device appears.If YY=5, the received frame information QC2RXINF app...

  • Page 49

    4293-E P-42SECTION 3 ALARM P0869 MCS ABSO SCALE initializeEeoemale2047An error occurred in initialization of ABSO SCALE.[Index]Axis name or none (spindle)[Character-string]None[Code]Same with <MCS Encoder initialize failed>[Probable Faulty Locations]• ABSO SCALE• Encoder link cables o...

  • Page 50

    4293-E P-43SECTION 3 ALARM PNone[Code]XXXXYYYYXXXX= PBU set value (Count number for one PG turn)YYYY= Actual count number[Probable Faulty Locations]• Faulty PG• Mismatch between the number of PG gear teeth and the servo data file data0873 MCS Motor over heatEeoemale2051The motor temperature...

  • Page 51

    4293-E P-44SECTION 3 ALARM P• FCP board0875 MCS Servo-link disconnectEeoemale2053The servo link is disconnected, disabling the servo unit from receiving commands from the NC.[Index]Axis name or none (spindle)[Character-string]None[Code]XXXXYYYYXXXX= Disconnected position0...Disconnected right...

  • Page 52

    4293-E P-45SECTION 3 ALARM P2: Wrongly set timing3: No transmission4: Calculation error5: Others[Probable Faulty Locations]• Servo data file not compatible with invertor unit• Invertor unit not compatible with NC software• Invertor unit control board• NC software0878 MCS Illegal command...

  • Page 53

    4293-E P-46SECTION 3 ALARM P• Servo data file• NC software0880 MCS Speed command overEeoemale2058Speed command value issued from the NC to the invertor unit exceeds the allowable limit.[Index]Axis name or none (spindle)[Character-string]None[Code]Speed command [(rev/4294967269)/Tv]rev= One ...

  • Page 54

    4293-E P-47SECTION 3 ALARM P• Motor encoder (BL motor)• Encoder link cables or connectors (BL motor)• PG or magnetic encoder (VAC motor)• PG or magnetic encoder cables or connectors (VAC motor)• Invertor unit control board0883 MCS Full-closed APA errorEeoemale2061Difference between th...

  • Page 55

    4293-E P-48SECTION 3 ALARM P +-2^-16[vr/3.2 ms/3.2 ms] = about 0.1 [rpm/ms]The code number 00000001 means that the error data is replaced by zero because of exponent underflow.[Probable Faulty Locations]The motor does not turn because of (mechanical lock or) application of large load.0886...

  • Page 56

    4293-E P-49SECTION 3 ALARM P0889 MCS Axis change control errorEeoemale2067NC failed to change axes normally.(This is not the alarm caused at MCS.)[Object]Newly selected axis[Character-string]None[Code]1: MCS was not reset within 10 seconds.2: The specified and active parameter numbers do not ma...

  • Page 57

    4293-E P-50SECTION 3 ALARM P0892 MCS Motor over loadEeoemale2070The motor load has exceeded the preset value, activating the overload protection function.[Index]Axis name or none (spindle)[Character-string]None[Code]YYYYZZZZYYYY-> Gamma of the protection curve used to detect overloadZZZZ->...

  • Page 58

    4293-E P-51SECTION 3 ALARM PX=2..Time outThe SVP does not send any response within 20 seconds at the time of start up. Minute investigation should be made tolocate the cause.Since the SVP cannot detect the start up signal, it cannot execute the start up sequence.YY=00ZZZZ=000000X=3..Double bus ...

  • Page 59

    4293-E P-52SECTION 3 ALARM P# 3...Illegal instruction error# 4...Zero divide error# 5...CHK instruction error# 6...TRAPV instruction error# 7...Privilege violation error# 8...Trace error# 9...Line 1010 emulator error#10...Line 1111 emulator error#11...Unused area error#12...Coprocessor illegal ...

  • Page 60

    4293-E P-53SECTION 3 ALARM PNone[Code]Variation of the position encoder values in hexadecimal [encoder unit/3.2ms]However, the following codes represents special meanings.FFFFFFFF= The variation has exceeded the liner axis stroke.FFFFFFFE= The variation has exceeded the rotary axis stroke (360 ...

  • Page 61

    4293-E P-54SECTION 3 ALARM P0909 SVP servo ampEeoemale2080Fatal abnormality has occurred in the servo amplifier.[Index]AXIS[Character-string]None[Code]YYZZYY = Internal error statusZZ = Servo amplifier IF status[Probable Faulty Locations]Drive unit of the of the problem axis.0910 SVP APA chec...

  • Page 62

    4293-E P-55SECTION 3 ALARM P• Refer to the cause of SVP DIFF over alarm.0912 SVP servo data settingEeoemale2083The SVP has received non-applicable servo data. This alarm occurs when an abnormal value is set in the NC as servo data orwhen the servo processor cannot receive the set data.Occurr...

  • Page 63

    4293-E P-56SECTION 3 ALARM P[Code]Hexadecimal number of the torque applied at the time of breakage0914 SVP F-TYPE encoder errorEeoemale2085Error compensation data for one turn cannot be set in the position encoder.[Index]AXIS[Character-string]None[Code]The number indicating the setting impossi...

  • Page 64

    4293-E P-57SECTION 3 ALARM P[Character-string]None[Code]Pattern of the read positional data (APA high-order digit)[Probable Faulty Locations]• Position encoder of the problem axis• SVP hardware of the problem axis• Timing signal from the NC unit0918 SVP cannot plant error offset dataEeoe...

  • Page 65

    4293-E P-58SECTION 3 ALARM P0922 SVP SA overloadEeoemale2093The servo amplifier has overheated exceeding the protection curve set in the SVP control software.[Index]AXIS[Character-string]None[Code]YYYYZZZZYYYY->gamma of the protection curve used for overload detectionZZZZ->theta [n] at o...

  • Page 66

    4293-E P-59SECTION 3 ALARM PNone[Probable Faulty Locations]Servo amplifier of the problem axis0926 SVP SA inverter bridge short circuitEeoemale2097The servo amplifier has detected short-circuit of the invertor bridge in the amplifier.A warning lamp IOCS on the servo amplifier is lit.[Index]AX...

  • Page 67

    4293-E P-60SECTION 3 ALARM P0930 SVP SA regenerative resistor overheatEeoemale2101The servo amplifier has detected excessive power consumption in the regenerative resistance of the amplifier. A warning lampDROH on the servo amplifier is lit.[Index]AXIS[Character-string]None[Code]None[Probable...

  • Page 68

    4293-E P-61SECTION 3 ALARM PAXIS[Character-string]None[Code]Alarm data[Probable Faulty Locations]SVP software controlling the problem axis0935 SVP data file readEeoemale2106At the start up of NC, data reading from SVMU was disabled.[Index]None[Character-string]None[Code]FFFF->Abnormality in ...

  • Page 69

    4293-E P-62SECTION 3 ALARM P0937 SVP data file checkEeoemale21081)Checking the SVP data file with the servo data file SVMU*.PBU. proved that the rotary/linear axis specifications registered inSVMU are different from those registered in the specification code file.2)The declared number of contro...

  • Page 70

    4293-E P-63SECTION 3 ALARM P4101FFFFIn the transmission of the VAC initialization data, the communication time out error occurred when the VAC initial-ization data transmission request command was executed.4102****In the transmission of the VAC initialization data, the communication error occur...

  • Page 71

    4293-E P-64SECTION 3 ALARM P• High-precision VAC drive unit• SPC6 card0939 VAC data file readEeoemale2110The NC has failed to correctly read the VAC data file.[Index]None[Character-string]None[Code]1->VAC data file is not found.2->Type of VAC data file is wrong.3->VAC data file is...

  • Page 72

    4293-E P-65SECTION 3 ALARM P• Faulty timing board (TFP board or FCP board)• Faulty servo processor (SVP board or FCP board)0942 Real time task loop errorEeoemale2113The real time task displayed in character strings has not been completed within a preset processing time.[Index]None[Character...

  • Page 73

    4293-E P-66SECTION 3 ALARM P[Index]None[Character-string]None[Code]XXYYZZXX =01->TFP data transmission module has stopped.02->Exception errorYY =01->FNP bus error02->Address error03->Illegal instruction04->Zero divide error05->CHK instruction error06->TRAPV instruction e...

  • Page 74

    4293-E P-67SECTION 3 ALARM P• If the NC had never run after installation of the control software until occurrence of this alarm, the TFP data file must bewrong in type or the control software did not include the file.[Measures to Take]• Reinstall the control software.• Check the control f...

  • Page 75

    4293-E P-68SECTION 3 ALARM P• If the NC had never run after installation of the control software until occurrence of this alarm, the I/O diagnostic data filemust be wrong in type or the control software did not include the file.[Measures to Take]• Reinstall the control software.• Check th...

  • Page 76

    4293-E P-69SECTION 3 ALARM P0953 Machine control processor startEeoemale2124At power supply, EC-P does not normally run, causing an exception alarm.[Index]None[Character-string]None[Code]XXYYXX->EC-P exception alarm codeYY->EC-P alarm data[Probable Faulty Location]Defective EC-P board0954...

  • Page 77

    4293-E P-70SECTION 3 ALARM PXX->Byte position of the mismatched specification code in the protected specification code fileYY->Mismatched specification code in the protected specification code fileZZ->Specification code data in the protected specification code file (before change)0956 ...

  • Page 78

    4293-E P-71SECTION 3 ALARM P[Measures to Take]Reinstall the control floppy.0959 IGF Specification unmatchingEeoemale2130In initialization of IGF, the NC has detected a mismatch in specifications.[Index]None[Character-string]None[Code]1->The common table in NCGEN does not match that in IGFMAI...

  • Page 79

    4293-E P-72SECTION 3 ALARM P0962 CCP Roader file loadEeoemale2133The load module file for the CCP loader cannot be loaded when the data communications function is activated with the DNC-Cspecification.[Index]None[Character-string]None[Code]1->No CCP loader software (CLA*.LOB)2->The CCP lo...

  • Page 80

    4293-E P-73SECTION 3 ALARM PNone[Character-string]Environmental variable in the wrong data line[Code]None[Probable Faulty Locations]Defective creation of the configuration file0966 Configuration file open errorEeoemale2137The NC has failed to properly open the configuration file.[Index]None[Cha...

  • Page 81

    4293-E P-74SECTION 3 ALARM P0969 Memory size is not sameEeoemale2140Mismatch between the operation buffer size and the capacity of the RAM actually set[Index]None[Character-string]None[Code]1 only[Probable Faulty Locations]The operation buffer specification code does not correctly correspond to...

  • Page 82

    4293-E P-75SECTION 3 ALARM PNone[Code]None0973 SVP INDEXING low-speed indexing overEeoemale2144In low-speed indexing controlled by SVP, the positioning speed has exceeded the preset speed.[Index]AXIS[Character-string]None[Code]None0974 SVP INDEXING unclamp time overEeoemale2145Unclamp operati...

  • Page 83

    4293-E P-76SECTION 3 ALARM P0977 SVP INDEXING incorrect commandEeoemale2148The NC has given an incorrect command to the positioning unit.[Index]AXIS[Character-string]None[Code]None[Probable Faulty Locations]The turret indexing command value exceeds the maximum number of points.0978 SVP INDEXIN...

  • Page 84

    4293-E P-77SECTION 3 ALARM P[Code]XYYZZZZX = 1->Hardware conditions are not met.YY= 1->The SVP board is not mounted.ZZZZ = 0000YY= 2->The SVP is in abnormal status.ZZZZ ->SVP statusYY= 3->Abnormality has occurred in the system bus related to the SVP hardware.ZZZZ ->System bus ...

  • Page 85

    4293-E P-78SECTION 3 ALARM P[Probable Faulty Locations]• Faulty PCB in the slider• Soiled main scale, low air supply pressure to the main scale unit, defective or broken air piping, clogged air filter, or con-taminated air• Condensation in the main scale unit[Measures to Take]• Change t...

  • Page 86

    4293-E P-79SECTION 3 ALARM P0987 SVP LE application errorEeoemale2156The connected optical linear encoder is of an inapplicable type.[Index]AXIS[Code]XXXXXXXXXXXXXXXX:->Connected optical linear encoder type0989 CPU information table data unsuitableEeoemale2157The CPU information table cont...

  • Page 87

    4293-E P-80SECTION 3 ALARM P1->Main board No. 12->Main board No. 23->Main board No. 34->Main board No. 45->Main board No. 56->Main board No. 6YY:1->Application information No. 1 table2->Application information No. 2 table3->Application information No. 3 table4->App...

  • Page 88

    4293-E P-81SECTION 3 ALARM P=3: Configuration file opening error=4: Wrong IP address specified at destination station=5: Wrong port number specified at destination station=6: Wrong port number specified at sending station=7: Logging ON/OFF setting error=8: Wrong IP address specified at se...

  • Page 89

    4293-E P-82SECTION 3 ALARM P1A:For OSP7030 / OSP730, pitch data of the slave axis is 0 although the axis changeover specification (function generationspecification B bit 0) is set.1B:For OSP7030 / OSP730, the rotary axis specification (servo data file) is not set although the point positioning ...

  • Page 90

    4293-E P-83SECTION 3 ALARM P[Measures to Take]Consult the machine maker.0999 Synchronous tap's data file readEeoemale2167The synchronous tapping data file cannot be read.[Index]None[Character-string]None[Code]XYYYYX= 1->The required file was not found.X= 2->An error occurred during file ...

  • Page 91

    4293-E P-84SECTION 4 ALARM ASECTION 4ALARM A1000 SVP start conditions uncertain ...................................................................... 911001 SVP processing trouble ................................................................................ 911002 SVP CON APA deviation .......

  • Page 92

    4293-E P-85SECTION 4 ALARM A1038 VAC alarm number; error ............................................................................ 1011039 VAC pulse generator count error ................................................................ 1011040 VAC motor acceleration rate .......................

  • Page 93

    4293-E P-86SECTION 4 ALARM A1078 SVP INDEXING servo data setting ............................................................. 1081080 VAC high speed motor parameter setting .................................................. 1091082 SVP LE sum check error .........................................

  • Page 94

    4293-E P-87SECTION 4 ALARM A1175 MCS Servo-link disconnect ......................................................................... 1211176 MCS Servo-link protocol error .................................................................... 1211177 MCS Servo data error .............................

  • Page 95

    4293-E P-88SECTION 4 ALARM A1235 Hydraulic unit preparation completion ........................................................ 1321236 Hydraulic unit pressure low ......................................................................... 1321239 Attached unit error 1 ..............................

  • Page 96

    4293-E P-89SECTION 4 ALARM A1296 Tailstock quill condition ............................................................................... 1411297 Chuck condition .......................................................................................... 1411299 Axis overload ......................

  • Page 97

    4293-E P-90SECTION 4 ALARM A1731 Work clamp miss ...................................................................................... 1511732 Machine axis travel limit over0 .................................................................... 1511733 PLC system data .........................

  • Page 98

    4293-E P-91SECTION 4 ALARM A1000 SVP start conditions uncertainEeoemale3001SVP hardware or software conditions were not met, which made it impossible to start up the SVP.[Index]AXIS[Code]XYYZZZZX=1->Hardware-related conditions are not met. YY=1->The SVP board is not mounted. ZZZZ=0000 ...

  • Page 99

    4293-E P-92SECTION 4 ALARM A1002 SVP CON APA deviationEeoemale3003Deviation between CON and APA has exceeded the preset limit.The deviation can be obtained by the formula: [Calculated value written in SVP]- [Actual position read from SVP].This value is monitored by the control software such as ...

  • Page 100

    4293-E P-93SECTION 4 ALARM A#18->Debugger interrupt alarm#19->INT2 loop error#20->INT5 loop error#21->Speed command calculation delay alarm#22->TRAP error#23->Floating-point coprocessor error#24->PMMU error#25->User interrupt error#26->Board version error#27->Memor...

  • Page 101

    4293-E P-94SECTION 4 ALARM Avalues (RCON). The NC then monitors the variation of the operation values at regular intervals. If the value changes in abnormalmanner for some reason exceeding the allowable limit, this alarm occurs.[Index]AXIS[Code]Absolute feedrate command value in hexadecimal [en...

  • Page 102

    4293-E P-95SECTION 4 ALARM A[Code]YYYYZZZZYYYY=Hexadecimal number of the high-order digit read from the encoderZZZZ=Hexadecimal number of the high-order digit obtained by calculation from the lower-order digit[Probable Faulty Locations]• Position encoder of the problem axis• SVP board of th...

  • Page 103

    4293-E P-96SECTION 4 ALARM A86->DIFF. MIN (DIFF-G variable)87->DIFF. MAX (DIFF-G variable)88->ATTF calculation constant89->Integration limit value100->FLSUD change timing abnormal101->1st speed change timing abnormal102->2nd speed change timing abnormal103->Exp change ti...

  • Page 104

    4293-E P-97SECTION 4 ALARM A1016 SVP F-TYPE encoder with shaft errorEeoemale3017It is impossible to set the rotation error compensation data of F type position encoder with shaft.[Index] AXIS[Code]The number indicating the setting disable reason.1->Data read disabled2->Data check sum erro...

  • Page 105

    4293-E P-98SECTION 4 ALARM A1022 SVP SA overloadEeoemale3023The servo amplifier has overheated exceeding the protection curve set in the SVP control software.[Index]AXIS[Code]YYYYZZZZYYYY:Set value of the protection curve used for overload detectionZZZZ:Detected value [n] at overload detection[...

  • Page 106

    4293-E P-99SECTION 4 ALARM AServo amplifier of the problem axis1027 SVP SA overheatingEeoemale3028The servo amplifier has detected overheating of the amplifier.A warning lamp SVTH on the servo amplifier is lit.[Index]AXIS[Probable Faulty Locations]Servo amplifier of the problem axis1028 SVP SA ...

  • Page 107

    4293-E P-100SECTION 4 ALARM A[Code]1->SVP hardware ID is not 1.[Probable Faulty Locations]• SVP board controlling the problem axis• A wrong version of SVP was mounted.1034 SVP control errorEeoemale3035The SVP board is in a trouble related to the axis control.[Index]AXIS[Code]Alarm data[P...

  • Page 108

    4293-E P-101SECTION 4 ALARM A1038 VAC alarm number; errorEeoemale3039The alarm number, which is sent from the VAC if a VAC alarm occurs, is not correct.[Code]XX Alarm number sent from the VAC[Probable Faulty Locations]• VAC board or VAC card• Measures to Take Replace the unit involved with ...

  • Page 109

    4293-E P-102SECTION 4 ALARM A[Measures to Take]Set a smaller feed unit amount.1043 VAC DIFF overEeoemale3044The DIFF over occurred in the C-axis control mode.[Code]XXXXXXXX DIFF when the alarm is detected (4 bytes)[Probable Faulty Locations]Mechanical factors such as insufficient lubricating oi...

  • Page 110

    4293-E P-103SECTION 4 ALARM A1->Undefined2->Mode transfer impossibleYY:1->Basic command2->Additional commandZZZZ:Command transmitted[Probable Faulty Locations]• VAC board or VAC card• Forbidden command is designated.[Measures to Take]Replace the unit involved with the error.1048...

  • Page 111

    4293-E P-104SECTION 4 ALARM A1053 VAC phase defectEeoemale3054One of three AC input phases is lost.[Probable Faulty Locations]Power failure1054 VAC arithmetic unit volt dropEeoemale3055Supply voltage for the control dropped.[Probable Faulty Locations]Faulty VAC board[Measures to Take]Replace th...

  • Page 112

    4293-E P-105SECTION 4 ALARM A1059 VAC VAC data settingEeoemale3060An error with the VAC PBU file data or the VAC online change parameter.[Probable Faulty Locations]VAC PBU file error[Measures to Take]Correct the PBU file data.1060 VAC VAC motor internal speed command overEeoemale3061Velocity co...

  • Page 113

    4293-E P-106SECTION 4 ALARM A[Probable Faulty Locations]VAC board, VAC card, wiring, loose connection[Measures to Take]• Replace the unit involved with the error.• Check wiring and connectors.1064 VAC watchdog errorEeoemale3065Watchdog timer is not cleared.[Probable Faulty Locations]VAC boa...

  • Page 114

    4293-E P-107SECTION 4 ALARM A11->Unused area12->Spurious interrupt error13->INT7 interrupt error14->Interrupt error15->TRAP instruction error16->User interrupt error[Probable Faulty Locations]VAC card[Measures to Take]Replace the unit involved with the error.1068 VAC speed dev...

  • Page 115

    4293-E P-108SECTION 4 ALARM A1074 SVP INDEXING unclamp time overEeoemale3075Unclamp operation is disabled or takes time.[Index]AXIS[Probable Faulty Locations]• Maladjustment of the unclamp limit switch• Low oil pressure• Malfunction of the solenoid valve1075 SVP INDEXING clamp time overEe...

  • Page 116

    4293-E P-109SECTION 4 ALARM A118->Unclamp check time11C->Clamp check time120->IN-P width200-3FC->Corresponds to the index positions, point numbers from 1 to 128.[Probable Faulty Locations]• The address data indicated in the alarm data is larger than the allowable limit or wrong....

  • Page 117

    4293-E P-110SECTION 4 ALARM A[Code]XXYYYYYYXX: Optical linear encoder alarm detected on occurrence of this alarmYYYYYY: Position data sent from the optical linear encoder on occurrence of this alarm1087 SVP LE initial transfer data errorEeoemale3086An error occurred in the initial transfer data...

  • Page 118

    4293-E P-111SECTION 4 ALARM A1-> End of file was received without loading any character.3-> End of file was received during file loading.9-> The device name was wrongly specified.A-> The file name was wrongly specified.B-> The file was not found.[Measures to Take]Consult the mach...

  • Page 119

    4293-E P-112SECTION 4 ALARM A[Character-string]Alarm number in decimal[Code]Alarm code[Probable Faulty Locations]Depends on the number indicated in the character-string. Inform us of the code and the character string.1151 MCS Exception processingEeoemale3095A fatal alarm occurred while the MCS ...

  • Page 120

    4293-E P-113SECTION 4 ALARM AIn the case of #12, #13, or #14,• Invertor unitIn other cases,• Invertor unit1152 MCS Processing troubleEeoemale3096MCS[Index]Axis name or none (spindle)[Character-string]None[Code]XXZZAAAAXX:04...The self-diagnostic data has an error. (ZZ: Received data)06...So...

  • Page 121

    4293-E P-114SECTION 4 ALARM AAxis name or none (spindle)[Character-string]None[Code]AAAAAAXXAAAAAA is always 0.X Alarm number 0:DC voltage alarm 1:Abnormal input voltage 2:Abnormal control power 3:Abnormal control status 4:Overload in regenerative circuit 5:Heat sink overheat 6:CPU error 7:Spar...

  • Page 122

    4293-E P-115SECTION 4 ALARM A• Power unit• Invertor unit control board1156 MCS DC-bus voltage alarmEeoemale3100The DC-bus voltage in the invertor unit has abnormally risen or fallen, disabling the invertor from supplying the current.[Index]Axis name or none (spindle)[Character-string]None[C...

  • Page 123

    4293-E P-116SECTION 4 ALARM AAxis name or none (spindle)[Character-string]None[Code]YYYYZZZZYYYY-> Gamma of the protection curve used to detect overloadZZZZ-> Internally calculated overload data[Probable Faulty Locations]• Invertor unit• Overload operation1160 MCS Supply voltage flutt...

  • Page 124

    4293-E P-117SECTION 4 ALARM AWinding-change magnet switch1163 MCS Encoder-link errorEeoemale3107An error occurred in the encoder communication link, disabling the encoder from detecting positioning speed.[Index]Axis name or none (spindle)[Character-string]None[Code]XXYYZZZZXX = FF (fixed)YY = 0...

  • Page 125

    4293-E P-118SECTION 4 ALARM AAxis name or none (spindle)[Character-string]None[Code]XXYYZZZZXX= Encoder link sequence number at the time of error detection0: Reset1: Network address setting2: Request of basic information on communication3: Change of communication version4: Acquisition of device...

  • Page 126

    4293-E P-119SECTION 4 ALARM A• Encoder link cables or connectors• Invertor unit control board1168 MCS ABSO SCALE errorEeoemale3112An error occurred in initialization of ABSO SCALE.[Index]Axis name or none (spindle)[Character-string]None[Code]Same with <MCS Encoder initialize failed>[P...

  • Page 127

    4293-E P-120SECTION 4 ALARM A1171 MCS Resolver alarmEeoemale3115The resolver does not send any signal.[Index]Axis name or none (spindle)[Character-string]None[Code]1 (fixed)[Probable Faulty Locations]Resolver trouble, or disconnection or contact failure of the resolver cable1172 MCS Pulse gener...

  • Page 128

    4293-E P-121SECTION 4 ALARM AYYYY= Bit number indicating the kind of communication error (Servo link error status at the time of error detection)bit 15 1: 2nd B-buffer errorbit 14 1: 2nd A-buffer errorbit 13 1: 1st B-buffer errorbit 12 1: 1st A-buffer errorbit 11 1: MT buffer errorbit...

  • Page 129

    4293-E P-122SECTION 4 ALARM A• Invertor unit control board not compatible with NC software• FCP board1177 MCS Servo data errorEeoemale3121The servo data sent from the NC for initialization or operation is not applicable to the invertor unit.If this alarm occurs after change of invertor unit...

  • Page 130

    4293-E P-123SECTION 4 ALARM A• NC software1179 MCS CON speed overEeoemale3123Increments for positioning command (SRCOND) issued from the NC to the invertor unit exceed the allowable limit.If this alarm occurs in the axis to be positioned, the servo data file has wrong data. (This is because t...

  • Page 131

    4293-E P-124SECTION 4 ALARM A1182 MCS APA speed overEeoemale3126The position encoder value (RAPA) changes as the motor rotates. The NC checks this change with preset frequency.This alarm occurs if the change per unit time exceeds the allowable range consecutively. For example, an axis feedrate ...

  • Page 132

    4293-E P-125SECTION 4 ALARM A• Resolver or magnetic encoder (VAC motor)• Resolver or magnetic encoder cables or connectors (VAC motor)• Invertor unit control board1185 MCS Velocity deviation overEeoemale3129Actual motor speed excessively deviates from the speed command.[Index]Axis name or...

  • Page 133

    4293-E P-126SECTION 4 ALARM A[Probable Faulty Locations]• Invertor unit control board• NC software1188 MCS Belt is brokenEeoemale3132Breakage of belt was detected in the belt-driven axis.[Index]Axis name or none (spindle)[Character-string]None[Code]Load torque (hexadecimal) at the time of a...

  • Page 134

    4293-E P-127SECTION 4 ALARM AYY = 0: Encoder link error status C2ERR established on detection of the errorYY = 1, 2, or 3: Transmitted frame information QC2MTINFYY = 4: Net address of the corresponding deviceYY = 5: Received frame information QC2RXINFYY = 6: Parameter number at which the error ...

  • Page 135

    4293-E P-128SECTION 4 ALARM A[Code]XYX:Read-in digitNo->Divided by "5"1->1st figure2->2nd figure3->3rd figure4->4th figure5->5th figure6->6th figureY:Read-in BCD dataA->through E Interface errorF->Encoder errorMeanwhile figures other than 0, 1, 3, 7, F given...

  • Page 136

    4293-E P-129SECTION 4 ALARM A[Related Specifications]MC-H series1204 Spindle drive unitEeoemale3244This is an alarm with the spindle motor drive unit.This alarm occurs if the VAC faulty signal is turned off.[Code]None->The faulty signal or normal signal is turned off.1->Velocity over sign...

  • Page 137

    4293-E P-130SECTION 4 ALARM AThe spindlehead cooling unit normal signal from the combination unit, which is installed at the back of the column, is turned off.(5) MDB-A/B, MCV-A/B, MCR, MCMThe cooler normal signal from the combination unit, which is installed at the rear of the table, is turned...

  • Page 138

    4293-E P-131SECTION 4 ALARM A1221 Carrier system checkingEeoemale3247This alarm occurs when the carrier system check mode is set by setting a proper parameter data to carry out adjustments for themachine of the DC or brushless motor specification for the ATC carrier. It does not usually occur ...

  • Page 139

    4293-E P-132SECTION 4 ALARM A• Setting error of carrier position, which is set by a system parameter• Malfunctioning LS1235 Hydraulic unit preparation completionEeoemale3250The hydraulic power unit pump motor ON signal is turned off.This signal is input from the combination unit, the APC hy...

  • Page 140

    4293-E P-133SECTION 4 ALARM A1243 CON 0 passEeoemale3156The SRSCON (final command value) value becomes negative. This alarm occurs if the SRSCON goes to the minus side frompoint A.EIOEMALE3001R01[Index]AXIS[Code]SRSCON value (hexadecimal) at an occurrence of alarm[Probable Faulty Locations]• ...

  • Page 141

    4293-E P-134SECTION 4 ALARM ASynchronization error allowable limit B: Optional parameter (word) No. 51[Code]Synchronization error at an occurrence of alarm in hexadecimal number[Probable Faulty Locations]• After power off, the master or the slave axis fell. Problem with the brake.• Load o...

  • Page 142

    4293-E P-135SECTION 4 ALARM ABit10->Zero divide exceptionBit11->Illegal instruction exceptionBit12->Address error exceptionBit13->Bus error exceptionBit15->RAM check error exception[Probable Faulty Locations]• Defective CRP• Defective operation panel[Measures to Take]• Repl...

  • Page 143

    4293-E P-136SECTION 4 ALARM A1257 Emergency stopEeoemale3166Emergency stop button is pressed.[Measures to Take]After removing the cause for which the emergency stop button has been pressed, reset it and then press the control powerON button.1261 Oil-air lube motor overloadEeoemale3254The oil-ai...

  • Page 144

    4293-E P-137SECTION 4 ALARM A 1 and 0 Regenerative repeater No. 2XX :bit 7-bit 0:Slave station numberThe slave se station number in which an error has been detected "00" is set when an error has been detected first in the mas-ter station. Data at bit 5 indicated whether an error...

  • Page 145

    4293-E P-138SECTION 4 ALARM A1->The temperature measured by TMP has exceeded the temperature monitoring range determined based on the referencechannel temperature.2->It is impossible to calculate the compensation amount suitable for the temperature measured by TMP. The measured tem-peratu...

  • Page 146

    4293-E P-139SECTION 4 ALARM A[Measures to Take]• Do not open the door during axis movement or spindle rotation• Replace the limit switch if defective. Adjust the dog position so that the confirmation limit switch comes ON when the dooris closed.1279 Axis movement prohibitionEeoemale3175Duri...

  • Page 147

    4293-E P-140SECTION 4 ALARM A[Measures to Take]• Replace the broken tool.• Set correct values.1291 B position errorEeoemale3179When B-axis was not located either in 0(-deg) or 90(-deg) position on DCC, skip feed (G31) was specified in automatic tool lengthoffset, automatic tool brakeage det...

  • Page 148

    4293-E P-141SECTION 4 ALARM A• Mount the workpiece before issuing the quill advance command.1296 Tailstock quill conditionEeoemale3260When there was a cycle instruction of the main shaft, tailstock quil was not a fixed place.[Index]None[character string]None[Code]1->Tailstock quil deviated...

  • Page 149

    4293-E P-142SECTION 4 ALARM A1301 External rotary table errorEeoemale3184The [NC DU OK] signal went OFF when the external rotary table is under NC control.Or, no response was sent within the preset time.[Index]None[Character-string]None[Code]XYYYYX: Axis No. being controlled 1:4th axis 2:5th ...

  • Page 150

    4293-E P-143SECTION 4 ALARM A1305 SPM Control errorEeoemale3188Fatal abnormality that the processing can not be continued by the control program of SUPER MAIN CARD(SPMC) was detected.[Code] 2000100: B Buffer Abnormality of Super Control Interval Code 2000200: B Buffer Abnormality of G code 2001...

  • Page 151

    4293-E P-144SECTION 4 ALARM A =02: Option MY is specified. =03: Option MZ is specified. =04: Option TS is specified.[Measures to Take]The above option codes are not usable for sequence restart from a NURBS block. Try the sequence number search withoutspecifying these option codes.1701 Emerge...

  • Page 152

    4293-E P-145SECTION 4 ALARM A[Probable Faulty Locations]• Defective setting of the system parameters• Malfunction of the limit switch[Measures to Take]Fine out which limit switch is activated on the check panel. Move the overtraveling axis toward the middle of the travel.[Referential Instr...

  • Page 153

    4293-E P-146SECTION 4 ALARM ANone[Probable Faulty Locations]Defective control device for a robot and loader1710 Excessive speed deviation Eeoemale3199No measures are take to this alarm.1711 Air pressure dropEeoemale3200Pressure of the air supplied to the machine is lower than the specified valu...

  • Page 154

    4293-E P-147SECTION 4 ALARM ANone[Character-string]None[Code]None[Measures to Take]Supply coolant to the tank.1716 Thru-the-tool coolant filter clog0Eeoemale3205The filter inside the through-the-tool coolant tank is clogged.[Index]None[Character-string]None[Code]None[Probable Faulty Locations]...

  • Page 155

    4293-E P-148SECTION 4 ALARM A1718 Hydraulic motor overload Eeoemale3207The overload relay protecting the hydraulic pump motor is tripped.[Index]None[Character-string]None : Combination unit’ATC’: Hydraulic power unit for ATC ’APC’: Hydraulic power unit for APC ’W’ : Hydraulic powe...

  • Page 156

    4293-E P-149SECTION 4 ALARM A[Character-string]None[Code]Difference between commanded position and encoder-detected position in hexadecimal number (reference unit)[Probable Faulty Locations]The axis (spindle or linear axis) was manually moved while D/U was OFF.[Measures to Take]Reset the NC.[Re...

  • Page 157

    4293-E P-150SECTION 4 ALARM A1726 Spindle overload Eeoemale3215The spindle load detection meter relay has been turned on due to overload.[Index]None[Character-string]None[Code]None[Probable Faulty Locations]• Cutting under overload condition• Setting error of the spindle load detection mate...

  • Page 158

    4293-E P-151SECTION 4 ALARM ANone[Character-string]None[Code]None1731 Work clamp miss Eeoemale3220With the chucking error detection specification, hte chick close end position confirmation LS is not turned on during the executionof the chuck close command.The control judges a status such as th...

  • Page 159

    4293-E P-152SECTION 4 ALARM A[Measures to Take]Reinstall control program1735 Hydraulic unit oil level lowEeoemale3224During hydraulic unit run, the oil level normal signal is turned off over 3seconds. This signal is input from the combination unit.[Index]None[Character-string]None : Combination...

  • Page 160

    4293-E P-153SECTION 4 ALARM A[Character-string]None[Code]None1740 Hydraulic pressure drop Eeoemale3229Hydraulic unit "Hydraulic pressure OK" signal is turned off over 3 seconds. [Index]None[Character-string]None : Combination unit’APC’: Hydraulic power unit for APC [Code]None1741...

  • Page 161

    4293-E P-154SECTION 4 ALARM A10=During APC running, "Robot/Loader retract position" signal was made OFF.1745 Locking switch N.G. Eeoemale3234Door lock pin movement was faulty.[Index]None[Character-string]None[Code]1=Door lock was uncompleted, 1 second passed since "Door unlock&qu...

  • Page 162

    4293-E P-155SECTION 4 ALARM ANone[Character-string]None[Code]None1752 Spindlehead lubricant pressure lowEeoemale3240Lubiricating oil is not correctly supplied to the spindlehead.The lubiricating oil supply normal signal detected by the pressure switch inside the spindlehead or the combination u...

  • Page 163

    4293-E P-156SECTION 5 ALRAM BSECTION 5ALRAM B2000 SVP start conditions uncertain .................................................................... 1682001 SVP processing trouble .............................................................................. 1682002 SVP CON APA deviation ........

  • Page 164

    4293-E P-157SECTION 5 ALRAM B2045 SVP LE comparator AD error ................................................................... 1772046 SVP LE face rotation error ........................................................................ 1782047 SVP LE initial transfer data error ............

  • Page 165

    4293-E P-158SECTION 5 ALRAM B2183 MCS Full-closed APA error ......................................................................... 1912184 MCS Over speed ........................................................................................ 1922185 MCS Velocity deviation over ................

  • Page 166

    4293-E P-159SECTION 5 ALRAM B2231 Direct of subscript ....................................................................................... 2032232 Bad value of system variable ...................................................................... 2042233 Local variable use over ................

  • Page 167

    4293-E P-160SECTION 5 ALRAM B2271 No system variable function ........................................................................ 2172272 No subprogram function ............................................................................. 2172273 No input/output variable function ............

  • Page 168

    4293-E P-161SECTION 5 ALRAM B2311 UNTENDED: no subprogram function ....................................................... 2352312 UNTENDED: center distance error over .................................................... 2362313 Area machining: no cycle axis command ............................

  • Page 169

    4293-E P-162SECTION 5 ALRAM B2372 Spindle orientation time over ...................................................................... 2462373 Spindle orientation answer error ................................................................. 2462374 No pallet program ..............................

  • Page 170

    4293-E P-163SECTION 5 ALRAM B2419 UGC: Command format ............................................................................. 2582420 UGC: Additional parameter ........................................................................ 2582421 UGC: Expression ................................

  • Page 171

    4293-E P-164SECTION 5 ALRAM B2465 DF ............................................................................................................... 2672466 L (Area machining) ..................................................................................... 2672467 Spindle deflection offset...

  • Page 172

    4293-E P-165SECTION 5 ALRAM B2517 No empty SAT ............................................................................................ 2742518 File open ..................................................................................................... 2742519 PRINT request ................

  • Page 173

    4293-E P-166SECTION 5 ALRAM B2559 DS ............................................................................................................... 2852560 Cycle time over ........................................................................................... 2852561 Bad direct ..............

  • Page 174

    4293-E P-167SECTION 5 ALRAM B2731 Data word: RP ........................................................................................... 2952732 Data word: RH ........................................................................................... 2962733 Data word: RS ...................

  • Page 175

    4293-E P-168SECTION 5 ALRAM B2000 SVP start conditions uncertainEeoemale4001SVP hardware or software conditions were not met, which made it impossible to start up the SVP.[Index]AXIS[Code]XYYZZZZX=1->Hardware-related conditions are not met. YY=1->The SVP board is not mounted. ZZZZ=0000 ...

  • Page 176

    4293-E P-169SECTION 5 ALRAM B2002 SVP CON APA deviationEeoemale4003Deviation between CON and APA has exceeded the preset limit.The deviation can be obtained by the formula: [Calculated value written in SVP] - [Actual position read from SVP].This value is monitored by the control software such a...

  • Page 177

    4293-E P-170SECTION 5 ALRAM B#14->Uninitialized interrupt error#15->Spurious interrupt error#16->Interrupt error#17->INT7 error#18->Debugger interrupt alarm#19->INT2 loop error#20->INT5 loop error#21->Speed command calculation delay alarm#22->TRAP error#23->Floatin...

  • Page 178

    4293-E P-171SECTION 5 ALRAM B2007 SVP CON speedEeoemale4008When the axis is in the target position or at a standstill, the target value, operation value, and actual position data are the same.With designation of an axis moving command, the NC starts calculating the path to the target position, ...

  • Page 179

    4293-E P-172SECTION 5 ALRAM B[Index]AXIS[Code]YYYYZZZZYYYY=Hexadecimal number of the high-order digit read from the encoderZZZZ=Hexadecimal number of the high-order digit obtained by calculation from the lower-order digit[Probable Faulty Locations]• Position encoder of the problem axis• SVP...

  • Page 180

    4293-E P-173SECTION 5 ALRAM B58->Notch filter constant group62->Encoder accuracy designation71->Amplifier communication speed86->DIFF. MIN (DIFF-G variable)87->DIFF. MAX (DIFF-G variable)88->ATTF calculation constant89->Integration limit value100->FLSUD change timing abn...

  • Page 181

    4293-E P-174SECTION 5 ALRAM B• Phase shift by collision of the problem axis2016 SVP F-TYPE encoder with shaftEeoemale4017It is impossible to set the rotation error compensation data of F type position encoder with shaft.[Index] AXIS[Code]The number indicating the setting disable reason.1->...

  • Page 182

    4293-E P-175SECTION 5 ALRAM BZZZZ:Average motor acceleration2022 SVP SA overloadEeoemale4023The servo amplifier has overheated exceeding the protection curve set in the SVP control software.[Index]AXIS[Code]YYYYZZZZYYYY:Set value of the protection curve used for overload detectionZZZZ:Detected ...

  • Page 183

    4293-E P-176SECTION 5 ALRAM B AXIS[Probable Faulty Locations]Servo amplifier of the problem axis2027 SVP SA overheatingEeoemale4028The servo amplifier has detected overheating of the amplifier.A warning lamp SVTH on the servo amplifier is lit.[Index]AXIS[Probable Faulty Locations]Servo amplifie...

  • Page 184

    4293-E P-177SECTION 5 ALRAM B2033 SVP board version errorEeoemale4034The SVP hardware version is wrong.[Index]AXIS[Code]1->SVP hardware ID is not 1.[Probable Faulty Locations]• SVP board controlling the problem axis• A wrong version of SVP was mounted.2034 SVP control errorEeoemale4035Th...

  • Page 185

    4293-E P-178SECTION 5 ALRAM BXX: Optical linear encoder alarm detected on occurrence of this alarm2046 SVP LE face rotation errorEeoemale4040An optical linear encoder generated a face rotation error.[Index]AXIS[Code]XXYYYYYYXX: Optical linear encoder alarm detected on occurrence of this alarm...

  • Page 186

    4293-E P-179SECTION 5 ALRAM B0009-> The simultaneous start mode ON command is issued during that mode.[Probable Faulty Locations]Programming error of the sequence for moving the PLC axis[Measures to Take]Consult the machine maker.2051 PLC axis continuous positioning overEeoemale4045The conti...

  • Page 187

    4293-E P-180SECTION 5 ALRAM B"#34"-> CPU address error"#35"-> DMA address error"#36"-> Undefined trap error"#37"-> Undefined interruption"#38"-> DMAC"#39"-> ITU"#40"-> SCI"#41"-> REF"#42...

  • Page 188

    4293-E P-181SECTION 5 ALRAM B[Probable Faulty Locations]• Faulty MCS controller• Faulty software2153 MCS CON APA deviationEeoemale4049Difference between CON and APA values has exceeded the allowable limit. The CON-APC deviation is the absolute value of dif-ference between [calculated value ...

  • Page 189

    4293-E P-182SECTION 5 ALRAM BIn the case of abnormal control power,• Power unitIn the case of low voltage,• Input voltage drop, power failure, blown fuse in input power circuit, or instantaneous power interruptionIn the case of high voltage• Power unit2155 MCS Converter-link errorEeoemale...

  • Page 190

    4293-E P-183SECTION 5 ALRAM BYYYY= V-phase current detected when this alarm occurs,expressed in signed hexadecimal [Tolerance: 3FFF][Probable Faulty Locations]• Invertor unit• Faulty motor insulation2158 MCS Power unit over heatEeoemale4054The invertor unit has detected excessive current fl...

  • Page 191

    4293-E P-184SECTION 5 ALRAM BNone[Code]1 (fixed)[Probable Faulty Locations]• Invertor unit• Servo data file2162 MCS Winding-change failedEeoemale4058The winding-change magnet switch does not come on.[Index]Axis name or none (spindle)[Character-string]None[Code]YYYYZZZZIf YYYY = 0000 ZZZZ = ...

  • Page 192

    4293-E P-185SECTION 5 ALRAM B• Encoder link cables or connectors• Invertor unit control board2164 MCS Encoder errorEeoemale4060The motor encoder has become unable to detect positional data.[Index]Axis name or none (spindle)[Character-string]None[Code]XXYYZZZZXX= Encoder error code depending...

  • Page 193

    4293-E P-186SECTION 5 ALRAM B2166 MCS Encoder with shaft errorEeoemale4062The encoder with shaft has become unable to detect positional data.[Index]Axis name or none (spindle)[Character-string]None[Code]Same with <MCS Encoder error>[Probable Faulty Locations]Encoder with shaft2167 MCS Enc...

  • Page 194

    4293-E P-187SECTION 5 ALRAM B2170 MCS Magnetic encoder alarmEeoemale4066The magnetic pulse generator has become unable to detect the motor speed. Or, the number of magnetic encoder gear teethdoes not match the data in the MCS data file.[Index]Axis name or none (spindle)[Character-string]None[Co...

  • Page 195

    4293-E P-188SECTION 5 ALRAM B[Character-string]None[Code]YYYYZZZZYYYY =0 (fixed)ZZZZ = 0010: Motor overheatZZZZ = 0011: Motor overheat is detected at the motor.ZZZZ = 0012: Motor overheat is detected at the position encoder.ZZZZ = 0013: Motor overhead is detected at the motor and the encoder.[P...

  • Page 196

    4293-E P-189SECTION 5 ALRAM B[Probable Faulty Locations]• Servo cables or connectors• Invertor unit control board• FCP board2176 MCS Servo-link protocol errorEeoemale4072The NC and the invertor unit exchange commands and responses at constant intervals according to the specified protocolt...

  • Page 197

    4293-E P-190SECTION 5 ALRAM BAxis name or none (spindle)[Character-string]None[Code]XXXXYYYYXXXX=10: Positioning mode Command point number over11: Positioning mode Negative command value12: Positioning mode Larger command value (specified position > 360 deg for rotary axis)13: Positio...

  • Page 198

    4293-E P-191SECTION 5 ALRAM B• Servo data file• NC software2181 MCS DIFF overEeoemale4077Axis movement caused a large positioning error.While the axis is in a target position or stopped, the target value and the calculated value are the same. With an axis movementcommand, the NC starts crea...

  • Page 199

    4293-E P-192SECTION 5 ALRAM BNumber of times the error has been detected[Probable Faulty Locations]• Synthetic offset data is not set at the full-closed loop encoder or wrong data is set.• ABSO SCALE or position encoder with shaft• Excessive lost motion in axis drive system (The motor is ...

  • Page 200

    4293-E P-193SECTION 5 ALRAM BXXXXYYYYXXXX: Detected torque (sum of torque data collected for 3.2 ms) ±2^-12[MAXTRQ] If Tv = 0.4 ms, the momentary maximum torque is H’7FFF. If Tv = 0.8 ms, the momentary maximum torque is H’3FFF.YYYY: Detected acceleration (average torque measured f...

  • Page 201

    4293-E P-194SECTION 5 ALRAM B• Faulty software2190 MCS independent encoder initEeoemale4086An error occurred during initialization of the MCS independent encoder.[Index]Axis name or none (spindle)[Character-string]None[Code]XXYYZZZZXX-> Encoder link sequence number at the alarm occurrence0...

  • Page 202

    4293-E P-195SECTION 5 ALRAM BIf the alarm code is "1" or "3", the position encoder may not be prope rly offset to zero.If the alarm code is "4", the servo data file may be defective.If the alarm code is "5" or "6", the motor coupling, encoder wi...

  • Page 203

    4293-E P-196SECTION 5 ALRAM BSchedule programProgram Example:N010 VSET V1=1N020 PSELECT LOADER.MINN030 PSELECT SHAFTR.MINN040 VSET V1=V1+1N050 IF [V3 LE 10]N020[Measures to Take]Designate the END command at the end of the schedule.Example:N010 VSET V1=1N050 IF [V3 LE 10]N020N060 END2203 Schedul...

  • Page 204

    4293-E P-197SECTION 5 ALRAM B2204 Expression: right sideEeoemale4093An illegal command is designated in the right side of the expression. Commands other than numerical data, input variables, sys-tem variables, common variables, local variables and extended address characters are designated.[Co...

  • Page 205

    4293-E P-198SECTION 5 ALRAM BVC1 = VGCOD [VC[10*2]]]Delete one "]" symbol.[Measures to Take]Correct the program.2207 Expression: factorEeoemale4096Subscript expression is wrong.[Code]None->More than one subscript expressionOthers->Result of subscript expression exceeds the rang...

  • Page 206

    4293-E P-199SECTION 5 ALRAM B2211 Program bad direct: M codeEeoemale4100Illegal M codeNumerical value greater than 399 or less than 00 is assigned to the address character M (00 < G < 399).[Code]Hexadecimal number of the designated M code[Probable Faulty Locations]Program error[Measures ...

  • Page 207

    4293-E P-200SECTION 5 ALRAM BProgram Example:VC1 = 123456789 (Too many digits)VC1 = 123.4.5 (More than one decimal point)[Measures to Take]Correct the numerical data.2217 Program bad direct: use of characterEeoemale4105Illegal symbols are designated.Designatable symbols are "]", &quo...

  • Page 208

    4293-E P-201SECTION 5 ALRAM B2->Nesting level of subprograms is higher than eight.3->The number of MODOUT statements is too large.4->Nesting level of MODIN mode is higher than eight.5->Mismatch in levels where MODIN mode is called and canceled.[Probable Faulty Locations]The number o...

  • Page 209

    4293-E P-202SECTION 5 ALRAM B2223 Branch (IF, GOTO): sequence nameEeoemale4110Command of sequence name for branching by IF or GOTO statement is wrong.[Code]1->Sequence name where branching is to be made is not designated.2->Designated sequence name is not found.[Probable Faulty Locations...

  • Page 210

    4293-E P-203SECTION 5 ALRAM B[Probable Faulty Locations]An M code macro is designated in the M= command.Program Example:M=VC1 (assume VC1=205)M=209[Measures to Take]Since "M=" type designation is not allowed when designating an M code macro, change the number specified following M= or...

  • Page 211

    4293-E P-204SECTION 5 ALRAM B[Code]When subscript outside the specified range is designated, hexadecimal number of the designated subscript[Probable Faulty Locations]• Subscript expression• Designation of variable (common variable, etc.) used as a subscriptProgram Example:VC[129] =1 (Range ...

  • Page 212

    4293-E P-205SECTION 5 ALRAM B[Code]Hexadecimal number of the ASCII code of the four characters specified following address character O[Probable Faulty Locations]• More than one program name is specified in a single program.• Program name is not designated at the beginning of the program.Pro...

  • Page 213

    4293-E P-206SECTION 5 ALRAM B2239 Unusable: OMITEeoemale4125The total number of specified R command sets exceeds 30.[Code]0->More than 30 sets of R commands are specified.Others->Command value in hexadecimalSetting error of R command range (1 <= R <= 65535)[Probable Faulty Location...

  • Page 214

    4293-E P-207SECTION 5 ALRAM B[Related Specifications]Coordinate computation function2242 Unusable: printEeoemale4128Illegal print statement[Code]1->Print is specified for other than variables, characters, numerical values, and extended address characters (FA, FB, RTand AG).4->Value VOK1 ...

  • Page 215

    4293-E P-208SECTION 5 ALRAM B• Or, the G131 command (Super Hi-NC control mode ON) block has a F command (Feedrate Upper Limit value) of whichvalue is out of the setting range.[Measures to Take]• In G01 mode, specify the feedrate by F command.• In G187 command block, specify the feedrate u...

  • Page 216

    4293-E P-209SECTION 5 ALRAM B• The G51 command block has an H command of which value is out of the setting range.• Or, the G11 (parallel/rotation shift of coordinate) block has a P command (rotation shift angle) of which value is out of thesetting range.• Or, the COPY or COPYE command blo...

  • Page 217

    4293-E P-210SECTION 5 ALRAM B• Or, refer to the instruction manual, and order the value of Minimum Block Length on Shape Reconstruction which isappropriate for the G131 command block.2250 Data word: 'RT'Eeoemale4136’RT’ command value for tool radius compensation revolution number is outs...

  • Page 218

    4293-E P-211SECTION 5 ALRAM B1->Only the X-axis has been designated.2->Only the Y-axis has been designated.3->Only the X- and Y-axis have been designated.4->Only the Z-axis has been designated.5->Only the X- and Z-axis have been designated.6->Only the Y- and Z-axis have been d...

  • Page 219

    4293-E P-212SECTION 5 ALRAM B• Check the setting of optional parameter (long word) No. 3.2256 Data word: plane selectionEeoemale4142With a plane designation G code(G17 (XY plane), G18 (ZX plane), G19 (YZ plane)), an axis parallel to the horizontal or verticalaxis of the plane selected, or th...

  • Page 220

    4293-E P-213SECTION 5 ALRAM B2260 Data word: mirror imageEeoemale4146Mirror image setting change command given in the mode in which such change is not allowed.[Code]1->In arc mode2->In coordinate calculation mode[Probable Faulty Locations]Program errorProgram Example:G0X0Y0G2X100I50F100G...

  • Page 221

    4293-E P-214SECTION 5 ALRAM B22->A chamfering command (CHFC, CHFR) is specified although the arbitrary angle chamfering specification is not pro-vided.23->G14 is specified although the axis name designation specification is not provided.24->A command between G180 and G185 is specified ...

  • Page 222

    4293-E P-215SECTION 5 ALRAM BNote: This alarm occurs if the cylindrical side surface machining is attempted on the machine not provided with a rotary axishaving a limited or unlimited rotation range.27->The 3-D coordinate conversion command (G69) is specified in the cylindrical side surface ...

  • Page 223

    4293-E P-216SECTION 5 ALRAM B2266 Main sequenceEeoemale4152Main sequence alarm[Code]12267 Sequence restartEeoemale4153Wrong sequence restart command[Code]X:1->CYCLE START pressed after executing restart command.2->CYCLE START pressed before pressing RESTART button after the completion of ...

  • Page 224

    4293-E P-217SECTION 5 ALRAM B2269 Minus travel limit overEeoemale4155Target command value is smaller than the negative travel limit value.[Index]AXIS[Code]1->The command value exceeds the negative travel limit while changeover of coordinate system is inhibited (during the exe-cution of fixed...

  • Page 225

    4293-E P-218SECTION 5 ALRAM BInput/output variables are used within a program.[Measures to Take]Change the program to delete the input/output variables from the program.2274 Backup data file writeEeoemale4160An error occurred while backup data is being written to the bubble memory. Writing to t...

  • Page 226

    4293-E P-219SECTION 5 ALRAM B1->At G178 or G179, the taper angle ’R’ command was executed simultaneously with the taper start/end point discrepancy ’J’(K,I) command.2->At G178 or G179, a calculation error occurred during analysis of the taper angle ’R’ command.Others->Comma...

  • Page 227

    4293-E P-220SECTION 5 ALRAM B2281 Fixed cycle: retract amountEeoemale4167Tool retract amount "d" set at NC optional parameter(long word) No. 1 and No. 2 is improper for the high-speed deep hole drillingcycle (G73) or the deep hole drilling cycle (G83).[Code]Command values in hexadeci...

  • Page 228

    4293-E P-221SECTION 5 ALRAM B[Probable Faulty Locations]No G71 command prior to calling M53 modeProgram Example:G81 X100 Y100 Z-60 R0 Q20 F100 M53 ^^^ No G71 prior to M53[Measures to Take]Designate the return point level with G71 before calling the M53 mode.2286 Fi...

  • Page 229

    4293-E P-222SECTION 5 ALRAM B-99999999 < I < 999999999 [microns, 1/1000-deg, 1/10000-deg][Code]FFFFFFFF->No I commandOthers->I command value (in hexadecimal)[Probable Faulty Locations]• No I command• Improper I command valueProgram Example:I200GRDX J200 K3 P2 F2000 No I comm...

  • Page 230

    4293-E P-223SECTION 5 ALRAM B• Specify a K command in the block which contains a mnemonic instruction.• Correct the K command value.[Related Specifications]Coordinate computation function2292 Coordinate computation: P commandEeoemale41781)No P command is specified in the block which contai...

  • Page 231

    4293-E P-224SECTION 5 ALRAM BDGRDX X500. Y500. I20000 J20000 K3 P2 Q100 R999999.(The data with a decimal point is handled in units of millimeters, thus causing an alarm.)[Measures to Take]• Check the R command value and the unit system.• Correct the program.[Related Specifications]Coordinat...

  • Page 232

    4293-E P-225SECTION 5 ALRAM B2298 Cutter radius comp.: operationEeoemale4184An error occurs during the floating-point calculation in the cutter radius compensation mode.Data for variables used for the cutter radius compensation function are first calculated by converting the variables into flo...

  • Page 233

    4293-E P-226SECTION 5 ALRAM B29->Computation error in calculating the execution data when canceling the cutter radius compensation function30->Computation error in calculating the decelerated feedrate31->Computation error in calculating the deceleration start point on a plane32->Com...

  • Page 234

    4293-E P-227SECTION 5 ALRAM B• G41, G42 or G43 command in the G02 or G03 mode.Program Example:G02 X_ Y_ I_ J_G42 X_ Y_ I_ J_G01 X_ Y_[Measures to Take]Specify G41, G42 or G43 command only in the G00 or G01 mode.[Related Specifications]3D tool offset function2302 Cutter radius comp.: numberEe...

  • Page 235

    4293-E P-228SECTION 5 ALRAM BAssume that "30" is set at D1.G00 X0 Y0G42 G01 X50 Y-50 F100X25X100 Y0[Measures to Take]• Reduce the cutter radius compensation data so that an interference will not occur. (Change a cutting tool also.)• Change the command values. (Tool paths will als...

  • Page 236

    4293-E P-229SECTION 5 ALRAM BSubprogram:OO10D->Cause: The touch probe fails to contact the workpiece while it is being fed at a middle approach speed (X-axis).Measures: Check the assumed gauging cycle target point.Check the POVT setting.Subprogram:OO10E->Cause: The touch probe fails to co...

  • Page 237

    4293-E P-230SECTION 5 ALRAM BCause: Touch probe contact is not detected in X-axis direction motion within a range of PUDT and POVT. (Contact valueerror)’;Measures: NC software error (change to software of new version) or faulty SVP board (replace.).Subprogram:OO1001D->Cause: Touch probe co...

  • Page 238

    4293-E P-231SECTION 5 ALRAM B2C->Cause: In the automatic tool length offset and automatic tool breakage detection cycles for the horizontal spindle in the radialdirection, the cutting tool fails to contact the sensor.Measures: Is the assumed cutter radius correct? (for tool length offset cyc...

  • Page 239

    4293-E P-232SECTION 5 ALRAM BMeasures: Check the following point:- Is the sensor signal correctly input to the NC?Subprogram:OO603C->Cause: When the gauging cycle is executed with a touch probe set in the vertical spindle of the MCM, swivel head orientationis not M75 position.Measures: On th...

  • Page 240

    4293-E P-233SECTION 5 ALRAM BCause: When the FM type touch probe was being fed at a final approach speed (Z-axis), a signal reception error occurred.Subprogram:OO10[Related Specifications]Untended specifications58->Cause: PLI is smaller than VMTL or [PLI-POVT] is smaller than [VMTL-10]. (10 ...

  • Page 241

    4293-E P-234SECTION 5 ALRAM Bmeasure: whether radius PDL of value of POVT whose a position of countermeasure: start is rid tool which or is confirmed isright adequate confirms.sub program name: OO71115->which did not touch a sensor in the 2nd approach of cause: Y directional automatic tool d...

  • Page 242

    4293-E P-235SECTION 5 ALRAM B2309 UNTENDED: tool breakageEeoemale4195This alarm occurs during the execution of the automatic tool breakage detection cycle (MSB) if any of the following are detected:a)The cutting tool fails to contact the touch sensor.b)The difference between the tool offset va...

  • Page 243

    4293-E P-236SECTION 5 ALRAM B4) The CALL OO30 (automatic tool breakage detection cycle) is executed although the control has no automatic tool breakagedetection specification.[Code]7[Probable Faulty Locations]• Setting error of VFST• Subprogram number settingProgram Example:CALL OO30 VFST=0...

  • Page 244

    4293-E P-237SECTION 5 ALRAM B• Specify the Z-axis (cycle axis).• Delete either the Z- or W-axis.2314 Area machining: tool dia. = 0Eeoemale4200The following commands are given in the area machining commands.1)Offset value of the D number specified is zero (0).2)When the offset value of the ...

  • Page 245

    4293-E P-238SECTION 5 ALRAM BNo R command[Measures to Take]Specify an R command.2317 Area machining: R level & finish surfaceEeoemale4203Commands which designate the R point level and finish surface level (cycle-axis command) at the same level are specified.[Code]1[Probable Faulty Location...

  • Page 246

    4293-E P-239SECTION 5 ALRAM B ^^^^^^^^ ^^^^^^^^ More than 2048[Measures to Take]Check the character-string length at the variable assigning area.2321 Data word: 'AG'Eeoemale4207When an angle command (AG) is specified, both of the axes on a plane are designated or neither of them is d...

  • Page 247

    4293-E P-240SECTION 5 ALRAM BProgram Example:PMIL X10 Y10 Z10 I100 J100 K1 Q5 R20 F400 WRITEAn alarm occurs because no D command is specified.[Measures to Take]Correct the D command value.2325 Area machining: 'I'Eeoemale4211In the area machining commands, no I command is specified or the sp...

  • Page 248

    4293-E P-241SECTION 5 ALRAM B2329 Area machining: 'Q'Eeoemale4215Wrong Q command (depth of cut) is specified: a negative value or a value which exceeds 99999999 after converted into microunit value.[Code]Command value in hexadecimal[Probable Faulty Locations]Q command in the area machining mod...

  • Page 249

    4293-E P-242SECTION 5 ALRAM BCancel the mode indicated above before calling the area machining mode.2333 Data word: indexing axis commandEeoemale4219An index table command is specified with other linear axis in the G01 mode.[Code]6[Probable Faulty Locations]Program errorProgram Example:G01 X10...

  • Page 250

    4293-E P-243SECTION 5 ALRAM BProgram Example:PRINT "ABCDEF..."Alarm occurs when more than 159 characters are specified.[Measures to Take]Correct the program.[Related Specifications]Print function2349 Tool change motor overloadEeoemale4434Overload of the tool change motor is detected.(...

  • Page 251

    4293-E P-244SECTION 5 ALRAM BFor PLC specification,the orient-stopped spindle has moved from the oriented position over the position set at the optionalparameter long word No. 20.Difference between actual and oriented spindle positions in hexadecimal (PLC specification)[Probable Faulty Location...

  • Page 252

    4293-E P-245SECTION 5 ALRAM B[Measures to Take]Turn off the power supply and cool the motor.2363 Area machining: M52 commandEeoemale4226M52 is specified when the cycle-axis is not the Z-axis.[Probable Faulty Locations]Axis designation or M52 commandProgram Example:G18 X0 Y0 Z100PMIL X100 Y50 Z...

  • Page 253

    4293-E P-246SECTION 5 ALRAM B• The ATC is operated for more than 30 minutes continuously (motor rating: 30 min).• Defective ATC hydraulic motor2369 Spindle REVERSE commandEeoemale4440On the AC spindle motor specification model, the spindle reverse rotation command is specified after changi...

  • Page 254

    4293-E P-247SECTION 5 ALRAM BZZ:bit0->The specified main file name and extended file name start with numerals.bit1->The device name is specified with more than 3 letters or a colon ’:’ is omitted after the device name.bit2->The specified program name does not begin with O.bit3->...

  • Page 255

    4293-E P-248SECTION 5 ALRAM B2380 AAC2 M commandEeoemale4444An M command related to the table type AAC operations is not correctly specified.[Code]1->M47 (next attachment adaptor command) is specified while the next AAC operation sequence number is not zero (0).2->M47 is specified while t...

  • Page 256

    4293-E P-249SECTION 5 ALRAM BDefective brushless drive unit (BDU-D)2388 Data word: 'E'Eeoemale4236Improper E command[Code]None->The G187 command block has no E command.2->During calculation of feedrate in thread cutting, the feedrate turned to a negative value.Others->Specified E com...

  • Page 257

    4293-E P-250SECTION 5 ALRAM BAA:Bit0->The main program has more than 31 sequence names.Bit1->A sequence name consists of more than five characters including N.Bit2->No subprogram name is specified following CALL statement.Bit3->A subprogram name consists of more than five characters...

  • Page 258

    4293-E P-251SECTION 5 ALRAM B 3->T 4->SBit data corresponding to the command whose answer signal is not returned is turned on (1). Indicated in one byte hexadec-imal. More than one bit may be turned on at the same time.[Probable Faulty Locations]• Operations of the commanded S, T,...

  • Page 259

    4293-E P-252SECTION 5 ALRAM B[Probable Faulty Locations]Output variable numberProgram Example VDOUT [**]Number not available by specification[Measures to Take]Change the output variable number to a number allowed by the specification.2397 Unusable: input variable NO.Eeoemale4245An input variab...

  • Page 260

    4293-E P-253SECTION 5 ALRAM BCharacter-string of picture hexa dataProgram Example:$ * D9 ^ Alarm code 1[Measures to Take]Specify the character-string correctly.2404 MSB reservedEeoemale4249This alarm outputs the check results of the Maker subprogram.[Code]Refer to the Operation Manual for the ...

  • Page 261

    4293-E P-254SECTION 5 ALRAM B2407 UGC: Delete syntaxEeoemale4252Illegal delete command designated[Code]User graphic internal code[Probable Faulty Locations][Character-string]designated in the DELETE statement in the user graphic commandProgram Example:DELETE PAINT[Measures to Take]Check the ch...

  • Page 262

    4293-E P-255SECTION 5 ALRAM B[Code]5 Number of digits overflow[Probable Faulty Locations]Numerical data in the user graphic commandChar[3 574 0]{CntInfo=’Program Example DEF WORKPS LL, [0, 0], [1000000, 100], 4END[Measures to Take]Check the numerical data and correct it.DEF WORKPS LL, [0, 0],...

  • Page 263

    4293-E P-256SECTION 5 ALRAM B2413 UGC: System variableEeoemale4258Illegal system variable designated[Code]0->No system variable number entry1->Entry of a number following system variable number2->Number of digits overflow in designating system variable number[Probable Faulty Locations...

  • Page 264

    4293-E P-257SECTION 5 ALRAM B[Related Specifications]Color, monochrome graphic display2416 UGC: Coordinate dataEeoemale4261Mismatch of the numbers of the left and right brackets, illegal factor code, inconsistency of the number of command coordinates[Index]TURRET[Code]1->Mismatch of the num...

  • Page 265

    4293-E P-258SECTION 5 ALRAM B :* DEF| :* END*-* More than 600 bytes[Measures to Take]Reduce the number of the commands in the command-string, or reduce the necessary memory space using the macro. :* DEF| :* END*-* Reduce to less than 600 bytes[Related Specifications]Color, monochrome graphic ...

  • Page 266

    4293-E P-259SECTION 5 ALRAM B1->More than one solution2->Program end code in expression3->Operand stack area over4->Mismatch between the numbers of operands5->Operand classification code stack area overMismatch between the numbers of left brackets "[" and right brackets...

  • Page 267

    4293-E P-260SECTION 5 ALRAM BColor, monochrome graphic display2424 Synchronous error recovering operationEeoemale4269This indicates that the synchronization error correction mode is ON or synchronized position shift amount setting mode is ON inthe synchronized axis control operation.[Code]Synch...

  • Page 268

    4293-E P-261SECTION 5 ALRAM BThe overload relay for the bed flush-out pump motor is tripped.[Related Specifications]Chip flush-out specification2430 Axis interlockEeoemale4272(1) A B-axis command is specified while the X-axis is not within 10 mm from the machine zero.(2) A B-axis command is spe...

  • Page 269

    4293-E P-262SECTION 5 ALRAM B2435 Work washing gun motor overloadEeoemale4451The overload relay for the workpiece washing gun motor is tripped.2436 Active tool NG2Eeoemale4273This alarm occurs when the life of a tool designated by a T code ends, and there is no available spare tool.[Code]AABB:A...

  • Page 270

    4293-E P-263SECTION 5 ALRAM B2442 Pattern cycle command missEeoemale4278There is an error in the data which is designated in interactive program B (solid shape machining/ridge machining cycle).There is erroneous data in interactive program B (solid shape machining/ridge machining cycle).[Code]X...

  • Page 271

    4293-E P-264SECTION 5 ALRAM B2449 Coordinate change operationEeoemale4283An error during floating-point arithmetic in coordinate conversionWhen obtaining values for the variables used in coordinate conversion, each variable is first converted into a floating point, and,after a value has been ob...

  • Page 272

    4293-E P-265SECTION 5 ALRAM B• Designate 1 or 2 for an RP command value.2454 Data word: WPEeoemale42872455 UpdateEeoemale4288An error caused during automatic selection of a schedule program precludes the completion of program selection.[Code]X:1->Not in the automatic operation mode2->Co...

  • Page 273

    4293-E P-266SECTION 5 ALRAM B[Probable Faulty Locations]Battery error of the touch probe[Related Specifications]Interactive gauging function2458 Interactive gauging: impossibleEeoemale4291While an axis is being fed (skip feed) in the workpiece gauging cycle of the semi-automatic mode (interact...

  • Page 274

    4293-E P-267SECTION 5 ALRAM B bit3->Attempt to calculate the square root of a negative value bit4->Attempt to divide a value by 0 bit5->Angle overflow in calculation of Sin,Cos,Tan,Cot valuesX=3 Calculation for chamfering An error occurred during calculation for automatic chamfering at...

  • Page 275

    4293-E P-268SECTION 5 ALRAM B2471 Cutting feed impossibleEeoemale4303G1, G2, or G3 command was issued while an axis is on its travel limit.[Code]12473 EC reset sequenceEeoemale4453NC reset processing by EC software took 5 seconds or over. The software is probably waiting for the answer from VAC...

  • Page 276

    4293-E P-269SECTION 5 ALRAM B[Code]1-> Specified with X-axis command.2-> Specified with Y-axis command.4-> Specified with Z-axis command.2481 DATA word:'WS'Eeoemale4309The WS command value is out of the setting range (larger than the maximum number of pallets).[Code]The alarm-caused WS...

  • Page 277

    4293-E P-270SECTION 5 ALRAM B[Code]Internal G code[Probable Faulty Locations]Commands not executable in I-PACK mode such as COPY, COPYE, IF, and GOTO Special G codeOperation Example: GOTO N001 in I-PACK mode[Measures to Take]Use these special codes in automatic operation mode.2493 buffer overEe...

  • Page 278

    4293-E P-271SECTION 5 ALRAM B2-> Two or more decimal points were found.3-> A figure with 10 or more digits was found.2500 READ communication errorEeoemale4320An error occurred during data reception.[Character-string]Error number (4 digits)[Code]Status code detected on occurrence of the er...

  • Page 279

    4293-E P-272SECTION 5 ALRAM B19-> The profile generation ON command (G138) was specified during slope machining.1A-> The profile generation ON command (G138) was specified during cylindrical side machining.1B-> The profile generation ON command (G138) was specified in the incremental c...

  • Page 280

    4293-E P-273SECTION 5 ALRAM B[Related Specifications]Scroll machining specification2511 Fine profile: 'F' commandEeoemale4329The high-speed profile generation (TPRF) command was specified with improper feedrate (F).[Code]F command in hexadecimal[Probable Faulty Locations]Faulty program[Program ...

  • Page 281

    4293-E P-274SECTION 5 ALRAM B11-> Axis command cancel mode (axis used for TPRF)[Probable Faulty Locations]Faulty program[Measures to Take]Check the program to correct errors.[Related Specifications]Scroll machining specification2515 TPRF:mismatch tool positionEeoemale4333Zero offset amount (...

  • Page 282

    4293-E P-275SECTION 5 ALRAM B[Code]1-> FOPENA/B was used to open two or more files.2-> FWRITC was used to open two or more files.3-> The writing file already exists.4-> The reading file is not found.5-> READ command was given without opening a file.6-> WRITE command was given ...

  • Page 283

    4293-E P-276SECTION 5 ALRAM B[Code]Faulty tool number in hexadecimal[Probable Faulty Locations]• All the tools in the specified tool group are faulty.• The magazine has no specified tools.[Measures to Take]Set nondefective tools of the specified group number in the magazine.2525 Tool input ...

  • Page 284

    4293-E P-277SECTION 5 ALRAM B[Index]None[Character-string]None[Code]1: Chuck open/close command during spindle rotation2: Spindle rotation command issued with the chuck open[Probable Faulty Locations]Wrong program operation[Measures to Take]Check if the program operation is correct.2529 R/W hea...

  • Page 285

    4293-E P-278SECTION 5 ALRAM BYY: YY application error NO.800000XX: XX communicative error NO.FFFFFFFFF: NC programmes over of a letter of 1 line are editedFFFFFFFFD: program buffer overflowXX=6F: Buffer in TCP/IP driver is too small.XX=72: Descriptor transferred to TCP/IP driver is faulty.XX=73...

  • Page 286

    4293-E P-279SECTION 5 ALRAM B[Character-string]None[Code]YY:YY application error NO.FFFFFFFF:NC programmes over of a letter of 1 line are editedFFFFFFFE:Inferiority of partial program which an error caused by a search of the several management tables YY=13: Incorrect channel number YY=16: Closi...

  • Page 287

    4293-E P-280SECTION 5 ALRAM B[Measures to Take] Specify a proper command in the program.2535 Fixed cycle 'LI'Eeoemale4347In the fixed cycle mode for controlling hole depth (G193), the LI command or its unit system is wrong. Or, the command wasspecified for an invalid fixed cycle.[Index]None[Ch...

  • Page 288

    4293-E P-281SECTION 5 ALRAM BNoneIn automatic operation/MDI operational mode, a movement order of axis table (A,C) that there is an opportunity outside wasperformed.2540 Compound fixed cycle modeEeoemale4352(Compound fixed cycle)[Index]None[Character-string]None[Code]1: Command was executed at ...

  • Page 289

    4293-E P-282SECTION 5 ALRAM B other: Command value was not within the following range: 99999999 >= command value > 0 (code is hexadecimal of command value.)2546 Compound fixed cycle axis commandEeoemale4358(Compound fixed cycle)Axis was not designated for the thread-cutting plane.G17:...

  • Page 290

    4293-E P-283SECTION 5 ALRAM B2550 Compound fixed cycle angleEeoemale4362(Compound fixed cycle)Alarm is activated when TAN(R) is [∞] at TRDL.Alarm is activated when COT(R) is [∞] at TRDT.[Index]None[Character-string]None[Code]According to calculation error status shown below.Calculation erro...

  • Page 291

    4293-E P-284SECTION 5 ALRAM B2553 Data word: BEeoemale4365Improper data was specified as a data word B.[Index]None[Character-string]None[Code]Specified B value in hexadecimal[Probable Faulty Locations]• A command value exceeding the range from -360 to 360 deg was specified in the part program...

  • Page 292

    4293-E P-285SECTION 5 ALRAM B[Probable Faulty Locations][Measures to Take]2558 HSEeoemale4369an order of HS in inadequate[Index]None[Chracter-String]None[Code]1:G15/G16 orders were performed by G41, 42, 44, 51, 11 or COPY mode.others:A hexadecimal number of value of HS which was ordered[Probabl...

  • Page 293

    4293-E P-286SECTION 5 ALRAM B3: RTI command is used in a program other than the interrupt program.[Probable Faulty Locations]• Programming error• Unregistered interrupt programs[Measures to Take]1: Delete M900 to M905 commands from the interrupt program.2: Register the programs O901 to O905...

  • Page 294

    4293-E P-287SECTION 5 ALRAM B102004D: NURBS (G132) mode is selected in the cylinder flank machining mode.1020060: NURBS (G132) mode is selected in the rapid traverse mode.[Probable Faulty Locations]Programming error[Measures to Take]Correct the program.2576 NURBS data word illegalEeoemale4377An...

  • Page 295

    4293-E P-288SECTION 5 ALRAM B2578 NURBS command errorEeoemale4379A wrong command was specified in the NURBS (G132) mode.[Code]1->The data word of X, Y, Z, Q, or R is not the numeric data.Example: X=VC1 (common variable)[Probable Faulty Locations]Programming error[Measures to Take]Correct the...

  • Page 296

    4293-E P-289SECTION 5 ALRAM B[Measures to Take]Refer to program or "POT NO./TOOL NO. Table"display.2704 Axis lube motor overload Eeoemale4383The overload relay for the axis lubrication motor is tripped.[Index]None[Character-string]None :X-,Y-,Z- axis’W’ :Cross rail[Code]None[Pro...

  • Page 297

    4293-E P-290SECTION 5 ALRAM B[Code]None[Probable Faulty Locations]• Defective coolant pump motor• Clogged lubrication pump2708 Thru-the-tool coolant motorEeoemale4387The overload relay for the through-the-tool coolant pump motor is tripped.[Index]None[Character-string]None[Code]None[Probabl...

  • Page 298

    4293-E P-291SECTION 5 ALRAM BNone[Code]None[Probable Faulty Locations]• The axis is not clamped mechanically.• Defective clamp or unclamp confirmation LS• Defective clamp or unclamp SOL2712 Unclamp confirmationEeoemale4391Unclamp confirmation signal is not output.The unclamp confirmation ...

  • Page 299

    4293-E P-292SECTION 5 ALRAM B[Character-string]None[Code]1:The T number specified is the same as the active tool number.2:T code is specified two times.3:T code is specified at other than ATC start position.4:T00 is specified during the execution of an ATC cycle.5:T00 is specified at other tha...

  • Page 300

    4293-E P-293SECTION 5 ALRAM B• Defective axis drive unit• Turn off power supply and cool the motor.2719 Sequence restartEeoemale4398Wrong sequence restart command[Index]None[Character-string]None[Code]None2720 Machine axis travel limit overEeoemale4399A machine axis (PLC axis) has exceeded ...

  • Page 301

    4293-E P-294SECTION 5 ALRAM BNone[Code]None[Probable Faulty Locations]• The filter is clogged.• Malfunction of the pressure switch for detecting• the clogged filter.[Measures to Take]Clean the filter.2724 Shower coolant motor overload Eeoemale4403Overload shower coolant motor[Index]None[C...

  • Page 302

    4293-E P-295SECTION 5 ALRAM B[Code]7:The spindle air blow command is issued during spindle rotation.2728 Machine system data code Eeoemale44071) There is a logical error in the data (such as Auto test data, Manual test data, Auto branch data, Manual branch data, and A/Bmode test data) used in ...

  • Page 303

    4293-E P-296SECTION 5 ALRAM B2732 Data word: RH Eeoemale4411Command value of attachment angle command RH is outside 0 degree to 359degrees , or an angle not supported by the specifi-cation is specified (usually, attachment is indexed in units of 5 degreed ,15 degrees or 45 degrees).[Index]None[...

  • Page 304

    4293-E P-297SECTION 5 ALRAM B2736 Work clump miss Eeoemale4415With the chucking error detection specification, hte chick close end position confirmation LS is not turned on during the executionof the chuck close command.The control judges a status such as that the working worlpiece has not bee...

  • Page 305

    4293-E P-298SECTION 5 ALRAM B[Code]None2742 Coolant unit Eeoemale4421Coolant unit normal signal was turned off over 3seconds.[Index]None[Character-string]None[Code]1=Scooping up pump ON comfirmation was OFF.2=Return pump ON confirmation was OFF.[Probable Faulty Locations]Faulty coolant unit274...

  • Page 306

    4293-E P-299SECTION 5 ALRAM B2746 Spindle gear change command Eeoemale4425(1) During spindle rotation, a spindle speed not available within the currently selected spindle speed range is commanded with Sand M commands.(2) When selecting a spindle speed, the designated spindle speed is outside th...

  • Page 307

    4293-E P-300SECTION 5 ALRAM BHexadecimal of RI command value caused an alarm2751 Limit confirmation impossible Eeoemale4430No signal is input from the swivel head position detection LS.During swivel head indexing, the counter data exceeds the designated swivel head position counter data by 45 ...

  • Page 308

    4293-E P-301SECTION 5 ALRAM BProblem with external coupled device2756 Sitting abnormal Eeoemale4463With the sitting error detection specification, the sitting end position confirmation PS is not turned on during the execution of thesitting detect command. The control judges a status such as th...

  • Page 309

    4293-E P-302SECTION 6 ALARM CSECTION 6ALARM C3000 SVP start conditions uncertain .................................................................... 3073001 SVP processing trouble .............................................................................. 3073002 SVP CON APA deviation ........

  • Page 310

    4293-E P-303SECTION 6 ALARM C3052 ACP diagnosis ........................................................................................... 3173150 MCS Undefined alarm number ................................................................... 3173151 MCS Exception processing .....................

  • Page 311

    4293-E P-304SECTION 6 ALARM C3189 MCS Axis change control error ................................................................... 3313190 MCS independent encoder init ................................................................... 3323191 MCS APA error .......................................

  • Page 312

    4293-E P-305SECTION 6 ALARM C3245 DNC machine No. is unsame ..................................................................... 3403246 DNC text format error ................................................................................. 3403247 DNC receive abort ..............................

  • Page 313

    4293-E P-306SECTION 6 ALARM C3710 Power saving ............................................................................................ 3513711 Chip flush-out motor overload .................................................................... 3513712 Chip conveyor motor overload .........

  • Page 314

    4293-E P-307SECTION 6 ALARM C3000 SVP start conditions uncertainEeoemale5001SVP hardware or software conditions were not met, which made it impossible to start up the SVP.[Index]AXIS[Code]XYYZZZZX=1->Hardware-related conditions are not met. YY=1->The SVP board is not mounted. ZZZZ=0000 ...

  • Page 315

    4293-E P-308SECTION 6 ALARM C3002 SVP CON APA deviationEeoemale5003Deviation between CON and APA has exceeded the preset limit. The deviation can be obtained by the formula: [Calculated valuewritten in SVP] - [Actual position read from SVP]. This value is monitored by the control software such ...

  • Page 316

    4293-E P-309SECTION 6 ALARM C#19->INT2 loop error#20->INT5 loop error#21->Speed command calculation delay alarm#22->TRAP error#23->Floating-point coprocessor error#24->PMMU error#25->User interrupt error#26->Board version error#27->Memory test error[Code]The CPU progr...

  • Page 317

    4293-E P-310SECTION 6 ALARM Cvalues (RCON). The NC then monitors the variation of the operation values at regular intervals. If the value changes in abnormalmanner for some reason exceeding the allowable limit, this alarm occurs.[Index]AXIS[Code]Absolute feedrate command value in hexadecimal [e...

  • Page 318

    4293-E P-311SECTION 6 ALARM C[Code]YYYYZZZZYYYY=Hexadecimal number of the high-order digit read from the encoderZZZZ=Hexadecimal number of the high-order digit obtained by calculation from the lower-order digit[Probable Faulty Locations]• Position encoder of the problem axis• SVP board of t...

  • Page 319

    4293-E P-312SECTION 6 ALARM C62->Encoder accuracy designation71->Amplifier communication speed86->DIFF. MIN (DIFF-G variable)87->DIFF. MAX (DIFF-G variable)88->ATTF calculation constant89->Integration limit value100->FLSUD change timing abnormal101->1st speed change timi...

  • Page 320

    4293-E P-313SECTION 6 ALARM C3016 SVP F-TYPE encoder with shaft errorEeoemale5017It is impossible to set the rotation error compensation data of F type position encoder with shaft.[Index] AXIS[Code]The number indicating the setting disable reason.1->Data read disabled2->Data check sum err...

  • Page 321

    4293-E P-314SECTION 6 ALARM C3022 SVP SA overloadEeoemale5023The servo amplifier has overheated exceeding the protection curve set in the SVP control software.[Index]AXIS[Code]YYYYZZZZYYYY:Set value of the protection curve used for overload detectionZZZZ:Detected value [n] at overload detection...

  • Page 322

    4293-E P-315SECTION 6 ALARM CServo amplifier of the problem axis3027 SVP SA overheatingEeoemale5028The servo amplifier has detected overheating of the amplifier.A warning lamp SVTH on the servo amplifier is lit.[Index]AXIS[Probable Faulty Locations]Servo amplifier of the problem axis3028 SVP SA...

  • Page 323

    4293-E P-316SECTION 6 ALARM C[Code]1->SVP hardware ID is not 1.[Probable Faulty Locations]• SVP board controlling the problem axis.• A wrong version of SVP was mounted.3034 SVP control errorEeoemale5035The SVP board is in a trouble related to the axis control.[Index]AXIS[Code]Alarm data[...

  • Page 324

    4293-E P-317SECTION 6 ALARM Cbit6-> 0 (fixed)bit7-> 0 (fixed)bit8-> 0 (fixed)bit9-> Exceptional processing of general illegal instruction in ACPBbit10-> Exceptional processing of slot illegal instruction in ACPBbit11-> CPU address error in ACPBbit12-> DMA address error in A...

  • Page 325

    4293-E P-318SECTION 6 ALARM C"#25"-> INT1 loop error"#26"-> Access denied"#27"-> Ram check error in initialization"#28"-> Party error"#29"-> Watchdog error"#30"-> IRQ7 interruption"#31"-> NMI interruption...

  • Page 326

    4293-E P-319SECTION 6 ALARM C6...Full-closed loop encoder value (4410)7...Semi-closed loop encoder value (4411)8...ODIFF (4415)10..APA in divided stroke (4404)11..Acceleration/deceleration time for positioning (4422)12..Zero offset amount13..In-position width (4420)14..Maximum of divided stroke...

  • Page 327

    4293-E P-320SECTION 6 ALARM C 1:Converter over current 2:Abnormal power element 3:Converter short circut 4:Abnormal regenerative circuit(type in power regenerative circuit) 5:Abnormal regenerative circuit(type in resistor discharge) X(alarm No.):4 Uncertain X(alarm No.):5 Uncertain X(alarm...

  • Page 328

    4293-E P-321SECTION 6 ALARM C[Index]Axis name or none (spindle)[Character-string]None[Code]XXXXYYYYXXXX= U-phase current detected when this alarm occurs,expressed in signed hexadecimal [Tolerance: 3FFF]YYYY= V-phase current detected when this alarm occurs,expressed in signed hexadecimal [Tolera...

  • Page 329

    4293-E P-322SECTION 6 ALARM C3161 MCS Power unit version errorEeoemale5051The invertor unit allowable current is smaller than the current limit specified in the servo data file.[Index]Axis name or none (spindle)[Character-string]None[Code]1 (fixed)[Probable Faulty Locations]• Invertor unit•...

  • Page 330

    4293-E P-323SECTION 6 ALARM Cbit 3 1: Double transmission errorbit 2 1: Double reception errorbit 1 1: Parity errorbit 0 1: Time-out error[Probable Faulty Locations]• Motor encoder, ABSO SCALE, encoder with shaft, or stand-alone encoder of the problem axis• Encoder link cables or co...

  • Page 331

    4293-E P-324SECTION 6 ALARM C[Probable Faulty Locations]• Motor encoder• Encoder link cables or connectors• Invertor unit control board3166 MCS Encoder with shaft errorEeoemale5056The encoder with shaft has become unable to detect positional data.[Index]Axis name or none (spindle)[Charact...

  • Page 332

    4293-E P-325SECTION 6 ALARM C[Probable Faulty Locations]• ABSO SCALE• Encoder link cables or connectors• Invertor unit control board3170 MCS Magnetic encoder alarmEeoemale5060The magnetic pulse generator has become unable to detect the motor speed. Or, the number of magnetic encoder gear ...

  • Page 333

    4293-E P-326SECTION 6 ALARM C3173 MCS Motor over heatEeoemale5063The motor temperature is abnormally high.[Index]Axis name or none (spindle)[Character-string]None[Code]YYYYZZZZYYYY = 0 (fixed)ZZZZ = 0010: Motor overheatZZZZ = 0011: Motor overheat is detected at the motor.ZZZZ = 0012: Motor over...

  • Page 334

    4293-E P-327SECTION 6 ALARM C[Code]XXXXYYYYXXXX= Disconnected position0...Disconnected right in front of the problem unit8000...Disconnected before the problem unitYYYY= Servo link error status at the time of error detection[Probable Faulty Locations]• Servo cables or connectors• Invertor u...

  • Page 335

    4293-E P-328SECTION 6 ALARM C3178 MCS Illegal commandEeoemale5068The NC and the invertor unit exchange commands and responses through the servo link. In this communication, the NC sent anabnormal or inexecutable command to the invertor unit.[Index]Axis name or none (spindle)[Character-string]No...

  • Page 336

    4293-E P-329SECTION 6 ALARM C[Code]Speed command [(rev/4294967269)/Tv]rev= One motor turn; Tv= Speed control frequency[Probable Faulty Locations]• Servo data file• NC software3181 MCS DIFF overEeoemale5071Axis movement caused a large positioning error.While the axis is in a target position ...

  • Page 337

    4293-E P-330SECTION 6 ALARM CNone[Code]Number of times the error has been detected[Probable Faulty Locations]• Synthetic offset data is not set at the full-closed loop encoder or wrong data is set.• ABSO SCALE or position encoder with shaft• Excessive lost motion in axis drive system (The...

  • Page 338

    4293-E P-331SECTION 6 ALARM CNone[Code]XXXXYYYYXXXX: Detected torque (sum of torque data collected for 3.2 ms) 2^-12[MAXTRQ] If Tv = 0.4 ms, the momentary maximum torque is H’7FFF. If Tv = 0.8 ms, the momentary maximum torque is H’3FFF.YYYY: Detected acceleration (average torque me...

  • Page 339

    4293-E P-332SECTION 6 ALARM C[Probable Faulty Locations]• Faulty MCS controller for PLC axis• Faulty software3190 MCS independent encoder initEeoemale5080An error occurred during initialization of the MCS independent encoder.[Index]Axis name or none (spindle)[Character-string]None[Code]XXYY...

  • Page 340

    4293-E P-333SECTION 6 ALARM C• Invertor unit control board• Servo data fileIf the alarm code is "1" or "3", the position encoder may not be properly offsetIf the alarm code is "4", the servo data file may be defective.If the alarm code is "5" or "...

  • Page 341

    4293-E P-334SECTION 6 ALARM C3213 No original command toolEeoemale5157The original tool for the active tool management number is not found.[Probable Faulty Locations]Original tool with the tool group number identical to the commanded active tool management number is not registered.[Measures to ...

  • Page 342

    4293-E P-335SECTION 6 ALARM CTurn the DNC mode ON after pressing the RESET button.[Related Specifications]DNC-B3219 OutsideEeoemale5086An alarm occurred with an external coupled device such as robot and loader.An alarm with the loader controller for the machine provided with the robot or the lo...

  • Page 343

    4293-E P-336SECTION 6 ALARM CBit1->No specified main programBit2->No specified subprogram fileBit3->No specified main subprogramBit4->No specified subprogramBit5->No M02 or M03 up to the end of main programBit6->No RTS up to the end of subprogramBit7->Program buffer cannot ...

  • Page 344

    4293-E P-337SECTION 6 ALARM CChip flush-out specifications3227 Warming upEeoemale5091Program selection for the warmup program cannot be carried out normally.[Code]1->The warmup program (W.WAF) is not registered in the bubble memory (BB1:).2->Although the warmup program is registered in th...

  • Page 345

    4293-E P-338SECTION 6 ALARM C[Measures to Take]Reset the cycle and restart it after all conditions have been set.3235 Panel/CRP receive errorEeoemale5097Error with the data received by the CRP transmitted from the operation panel.[Code]Bit0->ACIA reception errorBit1->Error with check sum ...

  • Page 346

    4293-E P-339SECTION 6 ALARM C3238 Chip cleanerEeoemale5165With the tap-hole chip cleaning specification, the chip cleaner is not functioning normally. This alarm occurs if the unit normal sig-nal from the chip cleaner is turned off.[Code]1->The dust collector operation confirmation signal r...

  • Page 347

    4293-E P-340SECTION 6 ALARM C• Replace the CCP board.• Check the CCP control program.3243 MOP communication errorEeoemale5103Communication error in communications with the MOP[Code]1->Check sum error occurred two times consecutively.2->Parity error occurred two times consecutively.3-&...

  • Page 348

    4293-E P-341SECTION 6 ALARM C[Code]Content differs depending on the text. For details, refer to the following.- For D,MST:1->Text is received during the interrupt mode, or reception is made without transmitting C,MST.2->In the request for automatic mode, response for single mode setting ...

  • Page 349

    4293-E P-342SECTION 6 ALARM C2->Reception is made before responding to the C,TLM command previously received.3-> 1 <= Transfer start tool number <= Transfer completion tool number <= QTLMX is not satisfied.- For D,TLM:1->Automatic mode is not selected.2->Upper and lower li...

  • Page 350

    4293-E P-343SECTION 6 ALARM CDNC-C3251 FMS operation mode selectEeoemale5111When the TRIAL MAC END button is pressed, none of the AUTO/MDI/MANUAL operation modes are selected.[Measures to Take]Press the first product machining button after selecting one of the AUTO, MDI and MANUAL modes.[Relate...

  • Page 351

    4293-E P-344SECTION 6 ALARM C• Defective communication board[Measures to Take]Reset the NC. If the same alarm still occurs, inspect the communication board, communication cables, and the temperaturesensor, and change them, if necessary.If the NC is reset after invalidation of the thermal devi...

  • Page 352

    4293-E P-345SECTION 6 ALARM C[Probable Faulty Locations]Defective text data received[Measure to Take]Investigate the host computer software.[Related Specifications]DNC-C3259 Compressor CheckEeoemale5118The air compressor maintenance request signal came ON. (user-selectable specification)3260 AD...

  • Page 353

    4293-E P-346SECTION 6 ALARM CTool management function3264 Spindle overloadEeoemale5121The load applied to the spindle has exceeded the value set as an overload monitor limit.[Code]XXXXYYYYXXXX: Parameter number for monitoring overloadYYYY: Overload rate (%) detected on occurrence of the alarm32...

  • Page 354

    4293-E P-347SECTION 6 ALARM CYY=16: Improper initialization parameters; Can’t close unopened line; Invalid program nameYY=11: Can’t open a line twiceYY=06: TCP/IP board initialization time-out (TCP/IP board inoperable); Can’t change the device name; Can’t release the pro-tection of the ...

  • Page 355

    4293-E P-348SECTION 6 ALARM CNone[Character-String]None[Code]None3275 Fixture shower coolant motor overloadEeoemale5174An overload for a peace possession shower motor worked.[Index]None[Character-String]None[Code]None[Probable Faulty Locations]• Inferiority of a peace possession shower motor....

  • Page 356

    4293-E P-349SECTION 6 ALARM CCheck the NC work counter screen and• Make the counter value smaller than the set value.• Make the set value smaller than the counter value.• Set 0 at the counter.3701 CPU temperature rising Eeoemale5128Temperature inside the control enclosure is higher than 6...

  • Page 357

    4293-E P-350SECTION 6 ALARM CThis alarm occurs when normal coolant level signal, output from the float switch in the coolant tank, is turned off when a coolantor through-the-tool coolant is designated.[Index]None[Character-string]None[Code]None[Measures to Take]Supply coolant.3705 ATC system co...

  • Page 358

    4293-E P-351SECTION 6 ALARM C[Index]None[Character-string]None[Code]None[Measures to Take]Supply the spindlehead lubricating oil.3709 Auto power shut-off impossibleEeoemale5136Auto power shut-off is attempted though the memory disk (MD) battery has done its service life.[Index]None[Character-st...

  • Page 359

    4293-E P-352SECTION 6 ALARM C[Index]None[Character-string]None[Code]None3714 APC system conditionEeoemale5141During execution of the APC cycle, APC input information does not match the APC sequence advance conditions. (indicated inthe APC input logic chart) in two minutes.[Index]None[Character-...

  • Page 360

    4293-E P-353SECTION 6 ALARM C[Index]None[Character-string]None[Code]None[Probable Faulty Locations]Problem with robot or loader3719 Coolant unit Eeoemale5146Coolant unit normal signal was turned off over 3seconds.[Index]None[Character-string]None[Code]1=Scooping up pump ON comfirmation was OFF...

  • Page 361

    4293-E P-354SECTION 6 ALARM C[Character-string]None[Code]None3724 VAC operation command mismatchEeoemale5151The condition in which the operation command output from the EC to the VAC and the response input from the VAC to the EC donot agree with each other has continued for more than 2 seconds....

  • Page 362

    4293-E P-355SECTION 6 ALARM C8:Timer is counting.XYYY:X=None, The input signal was not turn on.=1 , The input signal was not turn off.YYY=The address of input signal.3728 Oilmist unitEeoemale5176Oilmist unit unusual[Index]None[Character-string]None[Code]1: Oilmist oil level is low.2: Oilmist ...

  • Page 363

    4293-E P-356SECTION 6 ALARM C3733 Gauging NGEeoemale5181The result of gauging a work was not good.[Index]None[Character-string]None[Code]1:'Gauging NG' input signal was ON3734 Oil-air lubeEeoemale5182The oil-air lubricating unit is occured abnormal.[Index]None[Character-string]None[Code]25:Oil ...

  • Page 364

    4293-E P-357SECTION 7 ALARM DSECTION 7ALARM D4000 SVP start conditions uncertain .................................................................... 3624001 SVP processing trouble .............................................................................. 3624002 SVP CON APA deviation ........

  • Page 365

    4293-E P-358SECTION 7 ALARM D4052 PLC backup data file write .......................................................................... 3724053 VAC power supply voltage flutter over ....................................................... 3724054 ACP Key-code data receive error ..................

  • Page 366

    4293-E P-359SECTION 7 ALARM D4187 MCS Urgent-stop time over ........................................................................ 3864188 MCS Belt is broken ..................................................................................... 3874190 MCS independent encoder init ...............

  • Page 367

    4293-E P-360SECTION 7 ALARM D4240 Spindle neutral gear select condition .......................................................... 3984241 Tool clamp/unclamp operation condition .................................................... 3984242 G task stop ...............................................

  • Page 368

    4293-E P-361SECTION 7 ALARM D4702 Hydraulic oil temperature high .................................................................... 4064703 System check ........................................................................................... 4074704 ATC interlock releasing .................

  • Page 369

    4293-E P-362SECTION 7 ALARM D4000 SVP start conditions uncertainEeoemale6001SVP hardware or software conditions were not met, which made it impossible to start up the SVP.[Index]AXIS[Code]XYYZZZZX=1->Hardware-related conditions are not met. YY=1->The SVP board is not mounted. ZZZZ=0000 ...

  • Page 370

    4293-E P-363SECTION 7 ALARM D4002 SVP CON APA deviationEeoemale6003Deviation between CON and APA has exceeded the preset limit. The deviation can be obtained by the formula: [Calculated valuewritten in SVP] - [Actual position read from SVP]. This value is monitored by the control software such ...

  • Page 371

    4293-E P-364SECTION 7 ALARM D#19->INT2 loop error#20->INT5 loop error#21->Speed command calculation delay alarm#22->TRAP error#23->Floating-point coprocessor error#24->PMMU error#25->User interrupt error#26->Board version error#27->Memory test error[Code]The CPU progr...

  • Page 372

    4293-E P-365SECTION 7 ALARM Dvalues (RCON). The NC then monitors the variation of the operation values at regular intervals. If the value changes in abnormalmanner for some reason exceeding the allowable limit, this alarm occurs.[Index]AXIS[Code]Absolute feedrate command value in hexadecimal [e...

  • Page 373

    4293-E P-366SECTION 7 ALARM D[Code]YYYYZZZZYYYY=Hexadecimal number of the high-order digit read from the encoderZZZZ=Hexadecimal number of the high-order digit obtained by calculation from the lower-order digit[Probable Faulty Locations]• Position encoder of the problem axis• SVP board of t...

  • Page 374

    4293-E P-367SECTION 7 ALARM D58->Notch filter constant group62->Encoder accuracy designation71->Amplifier communication speed86->DIFF. MIN (DIFF-G variable)87->DIFF. MAX (DIFF-G variable)88->ATTF calculation constant89->Integration limit value100->FLSUD change timing abn...

  • Page 375

    4293-E P-368SECTION 7 ALARM D• Phase shift by collision of the problem axis4016 SVP F-TYPE encoder with shaft errorEeoemale6017It is impossible to set the rotation error compensation data of F type position encoder with shaft.[Index] AXIS[Code]The number indicating the setting disable reason....

  • Page 376

    4293-E P-369SECTION 7 ALARM DZZZZ:Average motor acceleration4022 SVP SA overloadEeoemale6023The servo amplifier has overheated exceeding the protection curve set in the SVP control software.[Index]AXIS[Code]YYYYZZZZYYYY:Set value of the protection curve used for overload detectionZZZZ:Detected ...

  • Page 377

    4293-E P-370SECTION 7 ALARM D AXIS[Probable Faulty Locations]Servo amplifier of the problem axis4027 SVP SA overheatingEeoemale6028The servo amplifier has detected overheating of the amplifier.A warning lamp SVTH on the servo amplifier is lit.[Index]AXIS[Probable Faulty Locations]Servo amplifie...

  • Page 378

    4293-E P-371SECTION 7 ALARM D4033 SVP board version errorEeoemale6034The SVP hardware version is wrong.[Index]AXIS[Code]1->SVP hardware ID is not 1.[Probable Faulty Locations]• SVP board controlling the problem axis.• A wrong version of SVP was mounted.4034 SVP control errorEeoemale6035T...

  • Page 379

    4293-E P-372SECTION 7 ALARM D2->The CCP control program cannot be loaded correctly.3->The CCP control program cannot be started correctly.4->The CCP communication channel cannot be opened correctly.5->A CCP self-diagnostics error occurred.6->An exception error occurred with the C...

  • Page 380

    4293-E P-373SECTION 7 ALARM D[Code]Alarm code[Probable Faulty Locations]Depends on the number indicated in the character-string.Inform us of the code and the character string.4151 MCS Exception processingEeoemale6043A fatal alarm occurred while the MCS invertor unit and MCS software are executi...

  • Page 381

    4293-E P-374SECTION 7 ALARM D• Invertor unitIn other cases,• Invertor unit4152 MCS Processing troubleEeoemale6044MCS[Index]Axis name or none (spindle)[Character-string]None[Code]XXZZAAAAXX:04...The self-diagnostic data has an error. (ZZ: Received data)06...Software sync bit or format code o...

  • Page 382

    4293-E P-375SECTION 7 ALARM D[Character-string]None[Code]AAAAAAXXAAAAAA is always 0.X Alarm number 0:DC voltage alarm 1:Abnormal input voltage 2:Abnormal control power 3:Abnormal control status 4:Overload in regenerative circuit 5:Heat sink overheat 6:CPU error 7:SpareY: Power unit status bit3 ...

  • Page 383

    4293-E P-376SECTION 7 ALARM D• Invertor unit control board4156 MCS DC-bus voltage alarmEeoemale6048The DC-bus voltage in the invertor unit has abnormally risen or fallen, disabling the invertor from supplying the current.[Index]Axis name or none (spindle)[Character-string]None[Code]XXXXYYYYXX...

  • Page 384

    4293-E P-377SECTION 7 ALARM D[Character-string]None[Code]YYYYZZZZYYYY-> Gamma of the protection curve used to detect overloadZZZZ-> Internally calculated overload data[Probable Faulty Locations]• Invertor unit• Overload operation4160 MCS Supply voltage flutterEeoemale6052The power uni...

  • Page 385

    4293-E P-378SECTION 7 ALARM D4163 MCS Encoder-link errorEeoemale6055An error occurred in the encoder communication link, disabling the encoder from detecting positioning speed.[Index]Axis name or none (spindle)[Character-string]None[Code]XXYYZZZZXX = FF (fixed)YY = 00: YY = 00: Error is detecte...

  • Page 386

    4293-E P-379SECTION 7 ALARM DNone[Code]XXYYZZZZXX= Encoder link sequence number at the time of error detection0: Reset1: Network address setting2: Request of basic information on communication3: Change of communication version4: Acquisition of device information5: Parameter change6: AT (auto) m...

  • Page 387

    4293-E P-380SECTION 7 ALARM D4168 MCS ABSO SCALE errorEeoemale6060An error occurred in initialization of ABSO SCALE.[Index]Axis name or none (spindle)[Character-string]None[Code]Same with <MCS Encoder initialize failed>[Probable Faulty Locations]• ABSO SCALE• Encoder link cables or co...

  • Page 388

    4293-E P-381SECTION 7 ALARM D[Index]Axis name or none (spindle)[Character-string]None[Code]1 (fixed)[Probable Faulty Locations]Resolver trouble, or disconnection or contact failure of the resolver cable4172 MCS Pulse generator count overEeoemale6064The PG (pulse generator) count value per one t...

  • Page 389

    4293-E P-382SECTION 7 ALARM Dbit 13 1: 1st B-buffer errorbit 12 1: 1st A-buffer errorbit 11 1: MT buffer errorbit 10 1: Relay processing errorbit 9 1: Data over error in data receiving part of interfacebit 8 1: Disconnectionbit 7 1: Address pointer errorbit 6 1: Modulation c...

  • Page 390

    4293-E P-383SECTION 7 ALARM D4177 MCS Servo data errorEeoemale6069The servo data sent from the NC for initialization or operation is not applicable to the invertor unit.If this alarm occurs after change of invertor unit, the servo data file is not applicable to the invertor unit.If this alarm o...

  • Page 391

    4293-E P-384SECTION 7 ALARM D4179 MCS CON speed overEeoemale6071Increments for positioning command (SRCOND) issued from the NC to the invertor unit exceed the allowable limit.If this alarm occurs in the axis to be positioned, the servo data file has wrong data. (This is because the invertor uni...

  • Page 392

    4293-E P-385SECTION 7 ALARM DThis alarm occurs if the change per unit time exceeds the allowable range consecutively. For example, an axis feedrate is abnor-mally high compared with the normal rapid feedrate, or the encoder value changes irregularly due to malfunction of the positionencoder.[In...

  • Page 393

    4293-E P-386SECTION 7 ALARM D• Invertor unit control board4185 MCS Velocity deviation overEeoemale6077Actual motor speed excessively deviates from the speed command.[Index]Axis name or none (spindle)[Character-string]None[Code]XXXXYYYYXXXX: Detected torque (sum of the torque data collected fo...

  • Page 394

    4293-E P-387SECTION 7 ALARM D• NC software4188 MCS Belt is brokenEeoemale6080Breakage of belt was detected in the belt-driven axis.[Index]Axis name or none (spindle)[Character-string]None[Code]Load torque (hexadecimal) at the time of alarm detection[Probable Faulty Locations]Broken belt4190 M...

  • Page 395

    4293-E P-388SECTION 7 ALARM D[Code]XXXXXXXX1: Linear axis divided travel over2: Overflow during conversion of semi-position from [pr] to pf].3: Underflow in synthesizing the axis data4: Overflow in synthesizing the axis data5: Overflow of input values used for hybrid control6: Overflow during i...

  • Page 396

    4293-E P-389SECTION 7 ALARM D[Code]The F value of the changing operation is displayed as a hexadecimal.[Probable Faulty Locations]• Feedrate command value is too large (perhaps due to a mistake in the unit setting system).• The maximum feedrate setting value is too small.• Override settin...

  • Page 397

    4293-E P-390SECTION 7 ALARM D[Measures to Take]The alarm is cleared at the completion of graphic data setting.[Related Specifications]Color graphic specification4211 SAC air pressure lowEeoemale6181Air pressure of the tool tip wear compensation SAC II unit is lowered.4212 Axis lube pressure unu...

  • Page 398

    4293-E P-391SECTION 7 ALARM D0->Operation preparation is not completed.1->CNC normal status2->Remote operation status3->Alarm statusZZ:Cause1->Check sum error has occurred Ne times (parameter set) continuously.2->Parity error has occurred Ne times (parameter set) continuously....

  • Page 399

    4293-E P-392SECTION 7 ALARM DDNC-B4220 DNC-B communication system abortEeoemale6098Unrestorable error has occurred in the protocol A. (This alarm is not cleared unless the power is turned on again.)[Code]1->No response is received when operation preparation is not completed.2->DSR OFF is ...

  • Page 400

    4293-E P-393SECTION 7 ALARM D4227 Axis clamp confirmationEeoemale6185With the PME type pallet pool specification, the stop pin IN confirmation limit switch is not turned on within ten seconds after thecompletion of pallet magazine positioning.[Character-string]APC4228 MOP overloadEeoemale610142...

  • Page 401

    4293-E P-394SECTION 7 ALARM D4231 DNC Illegal parameterEeoemale6104Online enable data or communications parameter is abnormal.Character string Message type indication consisting of 5 characters (transfer command or sub command)[Code]XYYYYX:Status1->Message effective identification table2->...

  • Page 402

    4293-E P-395SECTION 7 ALARM DD9->RC1 retry overDA->RC3 retry overDB->RC4 retry overDC->RC5 retry overDD->RC6 retry overDE->RC7 retry overDF->RC8 retry overE0->RC9 retry overE1->RC10 retry overE2->RC11 retry overE3->RC12 retry overE4->RC13 retry overE5->RC1...

  • Page 403

    4293-E P-396SECTION 7 ALARM D07->Data is being received.08->An interrupt request has been sent.09->Abort code has been sent in response to the interrupt request.FE->Forced interrupt is being requested.FF->Forced interrupt has been performed.YYYY:Status information0001->Send 00...

  • Page 404

    4293-E P-397SECTION 7 ALARM D0002->’ALM’0003->’MER’0004->’TER’0005->’CAR’0006->’SRT’0007->’FIN’0008->’STA’0009->’PST’000A->’OPC’000B->’OPE’000C->’NCP’000D->’RST’000E->’SEL’000F->’EXE’0010->’DE...

  • Page 405

    4293-E P-398SECTION 7 ALARM DYYYY:Status(details 3 of termination status)Not used[Probable Faulty Locations]• The power to the host computer is not turned on.• Communications cable• RS232C board4239 Rotary axis parameter backup dataEeoemale6112An error exists in the rotary axis parameter ...

  • Page 406

    4293-E P-399SECTION 7 ALARM D4246 File deletedEeoemale6118Power is shut off during file edit (I-MAP edit, ME edit).[Character-string]Deleted file nameFor details, refer to the notice file "ERROR.BAK" in the memory (MD0:), where the deleted edit file name and code arerecorded.[Code]1-&...

  • Page 407

    4293-E P-400SECTION 7 ALARM DAfter tool change, reset the NC if the program may be interrupted. To continue machining,if "temporary stop + spindle stop"has been specified, press the spindle stop release button on the additional panel to rotate the spindle. Then, edit the over-loaded t...

  • Page 408

    4293-E P-401SECTION 7 ALARM D• OSP7000M built-in type MOP-TOOL specification• Thermal deviation compensation function4262 Print data outputEeoemale6127An error occurred during printing of gauging data.This alarm is displayed when "0" is set at the optional parameter (bit) No. 16 b...

  • Page 409

    4293-E P-402SECTION 7 ALARM D[Probable Faulty Locations]The ACP board is equipped with an old version of ROM not usable for the 3-D graphic function of the machine.[Measures to Take]Change the ROM on the ACP board with a one designed for 3-D graphic function.4270 No magazine tool to be selected...

  • Page 410

    4293-E P-403SECTION 7 ALARM DNone[Code]XYX:Pulse handle number that caused this alarm 1 to 7 (pulse handle No. 1 to No. 7)Y:Pulse handle axis that caused this alarm 1 to 8 (pulse handle No. 1 axis to No. 8 axis)[Measures to Take]• Slowly rotate or stop the pulse handle.• Decrease the puls...

  • Page 411

    4293-E P-404SECTION 7 ALARM D[Related Specifications]Thermal deviation compensation4276 Axis overloadEeoemale6139Axis load has exceeded the value set for monitoring overload.[Index]None[Character-string]None[Code]XYYYYX: Overload monitor parameter No.YYYY: Load rate detected when the alarm occu...

  • Page 412

    4293-E P-405SECTION 7 ALARM D4280 Override range overEeoemale6143[Index]None[Character-string]None[Code]=1The rotary switch for controlling manual cutting feed rate has rotated over the stopper block.[Measures to Take]Retighten the stopper block in position.4281 Processing troubleEeoemale6144An...

  • Page 413

    4293-E P-406SECTION 7 ALARM D[Code] 1: An interrupt trigger is generated during MDI operation mode. 2: An interrupt trigger is generated during temporary stop. 3: An interrupt trigger is generated during manual interruption mode. [Measures to Take] 1: Select the automatic operation mode and pre...

  • Page 414

    4293-E P-407SECTION 7 ALARM D• Oil cooling fan motor is not operating.• Cooling filter is clogged.4703 System check Eeoemale6151This alarm shows that the system is under adjustment.[Index]None[Character-string]None[Code]Kind of adjustment4704 ATC interlock releasingEeoemale6152This alarm o...

  • Page 415

    4293-E P-408SECTION 7 ALARM D4708 Safety interlock Eeoemale6156On the machine designed in compliance with European safety standard, the operator door interlock function is activated (the dooris opened during machine operation). With this alarm, the NC displays the character string "DOOR&qu...

  • Page 416

    4293-E P-409SECTION 7 ALARM DNone4713 Please open door Eeoemale6161When the operator door or the front door open/close confirmation limit switches are at close end with the power ON, the doorinterlock type S function displays this message, requesting the operator to open the door to check if th...

  • Page 417

    4293-E P-410SECTION 7 ALARM DNone[Code]None4719 Coolant unit unusualEeoemale6167[Index]None[Character-string]None[Code]1:The signal that cooling unit for coolant was correct turned off.4720 NC START ineffecitive Eeoemale6168When NC start is ineffective, "NC START"PB was pushed.If &qu...

  • Page 418

    4293-E P-411SECTION 7 ALARM D[Character-string]None[Code]None[Measures to Take]Index the table correctly by given the index command again.4724 Quality counterEeoemale6172[Index]None[Character-string]None[Code]1=Work counter machine stop was ON.10=Work counter abnormal was ON.4725 PPC cycle star...

  • Page 419

    4293-E P-412SECTION 7 ALARM DNone[Code]None4730 Feed rate limitation Eeoemale6178Running in Setting/Test mode[Index]None[Character-string]None[Code]None4731 Please close door Eeoemale6179[Index]None4732 Lube unitEeoemale6189Oil level in the lubricating oil tank is low.[Index]None[Character-str...

  • Page 420

    4293-E P-413SECTION 7 ALARM D4735 Lube oil drain tank overflowEeoemale6192The drain oil overflow signal defected by the float switch in the lubricating drain tank is turned on.[Index]None[Character-string]None[Code]None4736 Manual interupptionEeoemale6193MID. AUTO MANUAL key was pressed during ...

  • Page 421

    4293-E P-414SECTION 8 ERRORSSECTION 8ERRORS0100 Device name ............................................................................................... 4320101 Sector device name .................................................................................... 4320102 Print device name ....

  • Page 422

    4293-E P-415SECTION 8 ERRORS0201 MAB full ...................................................................................................... 4420202 Record buffer over flow ............................................................................... 4420203 Load object address .............

  • Page 423

    4293-E P-416SECTION 8 ERRORS0320 RS232C terminal not ready ........................................................................ 4520321 RS232C ready status time out .................................................................... 4520322 RS232C ready interrupt time out ....................

  • Page 424

    4293-E P-417SECTION 8 ERRORS0405 Floppy disc initialize .................................................................................... 4630406 Patch sector area ........................................................................................ 4640407 Patch sector address over ........

  • Page 425

    4293-E P-418SECTION 8 ERRORS5233 Axis spec .................................................................................................... 4735234 EIA code ..................................................................................................... 4735235 RS232C channel in use .....

  • Page 426

    4293-E P-419SECTION 8 ERRORS5273 Effective group No. 0-255 ........................................................................... 4815274 Minus value invalid ..................................................................................... 4815275 Max number of registered tools ..........

  • Page 427

    4293-E P-420SECTION 8 ERRORS5313 Not found pitch comp. data file ................................................................... 4895314 LASER measurement execute ................................................................... 4895315 Solid shape command ...................................

  • Page 428

    4293-E P-421SECTION 8 ERRORS5353 Select plane tool length offset unmatching ................................................. 4965354 Select plane maximum return unmatching ................................................. 4975355 Initial program load ..............................................

  • Page 429

    4293-E P-422SECTION 8 ERRORS5393 WRONG ADDRESS ................................................................................... 5055394 NO-PROGRAMED REF. ............................................................................ 5065395 NO-PROGRAMED COEF. .....................................

  • Page 430

    4293-E P-423SECTION 8 ERRORS8106 File data ...................................................................................................... 5168107 File open ..................................................................................................... 5168108 File write .............

  • Page 431

    4293-E P-424SECTION 8 ERRORS9016 Buffer overflow. Can not copy anymore. ..................................................... 5219017 Input file name illegal. ................................................................................. 5219018 Input impossible except for numerals. ...........

  • Page 432

    4293-E P-425SECTION 8 ERRORS9063 Can not change device name and directory name. .................................... 5289064 Not a text file. Can not verify. ...................................................................... 5299065 It's not a sequence name or numerals. .......................

  • Page 433

    4293-E P-426SECTION 8 ERRORS9418 PNO. must not exceed the maximum number of pallet stations. ................ 5349419 Input PNO. .................................................................................................. 5349420 Input MAC.-SCH.NO. ...........................................

  • Page 434

    4293-E P-427SECTION 8 ERRORS99107 Undefined exception ................................................................................. 54299108 Undefined TRAPA .................................................................................... 54299109 Undefined interruption ....................

  • Page 435

    4293-E P-428SECTION 8 ERRORS99455 Not enough VRAM for font ........................................................................ 54999456 Check the control software. ..................................................................... 54999457 Not enough memory for font tag .................

  • Page 436

    4293-E P-429SECTION 8 ERRORS99532 efrpc_bind: Channel not connected. ......................................................... 55599533 efrpc_service: Unknown special RPC. ...................................................... 55599534 efrpc_service: Unknown VARSIG in arg. ........................

  • Page 437

    4293-E P-430SECTION 8 ERRORS99575 resFile_create_resrc: Type ID NULL resource. ........................................ 56199577 resFile_ext: Not resource file .................................................................... 56199578 FORCE-TALK format resource file. ...........................

  • Page 438

    4293-E P-431SECTION 8 ERRORS99640 Invalid format for initialize. ........................................................................ 56799650 Invalid file for protect. ................................................................................ 56799651 Write protected. ..................

  • Page 439

    4293-E P-432SECTION 8 ERRORS0100 Device nameEeoemale7001Wrong device name is designated, or when a device name is designated after renaming it in a renaming operation, it differs fromthe source device name.[Character-string]Designated device name or None[Code]1->Mismatch of device name in re...

  • Page 440

    4293-E P-433SECTION 8 ERRORS[Measures to Take]Refer to the instructions for individual commands.0106 Command characterEeoemale7005A command that is not in the command table has been designated.[Character-string]Command characters which have been input[Code]None[Probable Faulty Locations]• Spe...

  • Page 441

    4293-E P-434SECTION 8 ERRORS[Measures to Take]Refer to the instructions for individual commands.0110 File attributeEeoemale7008An attempt is made to read a file other than a sequential file and contiguous file, or an attempt is made to read a contiguous file inthe sequential file reading proces...

  • Page 442

    4293-E P-435SECTION 8 ERRORS0114 Error-map informationEeoemale7011Wrong sector identification name for error map information (containing faulty track information) of the IBM-formatted floppy disk[Code]0->Wrong sector identification name1->Wrong information on faulty track[Probable Faulty ...

  • Page 443

    4293-E P-436SECTION 8 ERRORS[Character-string]None[Code]The number of sectors designated[Probable Faulty Locations]The number of sectors has not been set at the parameter.0127 Memory disk battery voltage lowEeoemale7016The battery voltage of the memory disk (MD) is low.[Character-string]None[Co...

  • Page 444

    4293-E P-437SECTION 8 ERRORS• In case the data on the floppy disk may be deleted, initialize the floppy disk then try read/write operation again.0131 Floppy disc access sector overEeoemale7019A value greater than the actual floppy disk capacity is designated for the access sector using the pa...

  • Page 445

    4293-E P-438SECTION 8 ERRORS0134 Floppy disc recalibrateEeoemale7022Error during floppy disk recalibration ("Recalibration" means the operation to move the FDD head to the track number 0 position.)[Character-string]None[Code]XXXX->Contents of result status 0, 1 of floppy disk drive...

  • Page 446

    4293-E P-439SECTION 8 ERRORS0138 Floppy disk write protectEeoemale7026Writing onto the floppy disk is impossible. [Character-string]None[Code]None [Probable Faulty Locations]The floppy disk is write-protected. [Measures to Take]Change the disk to write-enabled (by handling the protect notch on...

  • Page 447

    4293-E P-440SECTION 8 ERRORS• Check the switch settings at the main board.• Replace the main board, or main card 1 or 5.0148 Program loadEeoemale7030The loading file failed to properly load a program file. [Character-string]None[Code]1->The program file has ended before even one characte...

  • Page 448

    4293-E P-441SECTION 8 ERRORSCheck the contents of the file to be loaded. 0152 Memory disk ROM writeEeoemale7034An error occurred in data writing onto the memory disk (FR). [Character-string]Start of writingThe transition from read-only mode to program mode does not take place. End of writingTh...

  • Page 449

    4293-E P-442SECTION 8 ERRORS[Probable Faulty Locations]The VID data in the memory has been destroyed.[Measures to Take]Check the data in the sector 0(VID).[Referential Instruction Manual]OSP File Structure0200 System file dataEeoemale7038Although an attempt is made to load the system software (...

  • Page 450

    4293-E P-443SECTION 8 ERRORS• An attempt to load the load object file to main memory.[Measures to Take]Check the contents of the first data block (DB 0) of the program file in question .[Referencial Document]OSP file structure0204 Load object attributeEeoemale7042Error in load object attribut...

  • Page 451

    4293-E P-444SECTION 8 ERRORS0250 Selected numberEeoemale7045An unspecified number was selected in the install mode. [Character-string]None [Code]None [Measures to Take]Select the required number from the specified numbers.0252 Memory disk RAM formatEeoemale7046The memory disk (MD) management da...

  • Page 452

    4293-E P-445SECTION 8 ERRORS• An FR-part-file stored in the control floppy disk for FR has a wrong number.• An FR-part-file stored in the control floppy disk for FR is destroyed.[Measures to Take]Change the control floppy disk for FR. 0257 FR-part-file load addressEeoemale7050An FR-part-fil...

  • Page 453

    4293-E P-446SECTION 8 ERRORSNone [Code]Undeleted address [Probable Faulty Locations]Faulty memory board or ROM card[Measures to Take]Change the memory board or ROM card. 0263 File headerEeoemale7054The installation data file or format data file has a wrong header. [Character-string]File header[...

  • Page 454

    4293-E P-447SECTION 8 ERRORSNone [Code]None [Probable Faulty Locations]Memory disk (MD) battery life[Measures to Take]Change the battery with a new one.0300 Device nameEeoemale7653The specified device name is wrong. - The device name specified for renaming differs from the source device name.- ...

  • Page 455

    4293-E P-448SECTION 8 ERRORSNone[Probable Faulty Locations]Contents of print device name variable PPRDV4 have been destroyed.0303 Reader device nameEeoemale7062A device name not allowed as a tape reader device name is designated in one of parameters to be transferred to tape readerdriver routin...

  • Page 456

    4293-E P-449SECTION 8 ERRORS[Character-string]Programmed Command[Code]1->Incorrect data size2->Memory verify error3->Wrong delimiter code4->Address of an odd number designated for other than byte[Probable Faulty Locations]• Grammatical error in the command input through the keyboa...

  • Page 457

    4293-E P-450SECTION 8 ERRORSNone[Code]Necessary number of remaining sectors[Probable Faulty Locations]• Available area is not sufficient.• SAT sector information of the device has been destroyed.[Measures to Take]• Delete unnecessary files.• Check the available area size with the FREE c...

  • Page 458

    4293-E P-451SECTION 8 ERRORS[Measures to Take]Check the contents of the error map sector.0315 Volume-label informationEeoemale7074Wrong volume label information* on the IBM-formatted floppy disk *Equivalent VID of OSP-formatted floppy disk[Character-string]None[Code]None[Probable Faulty Loca...

  • Page 459

    4293-E P-452SECTION 8 ERRORS[Character-string]None[Code]Contents of RS232C interface statusBit 0->DR signal ON/OFF status[Probable Faulty Locations]• Defective device • Defective communication cables• Connection specification is not proper.[Measures to Take]• Check the wiring diagram...

  • Page 460

    4293-E P-453SECTION 8 ERRORS• Improper setting at check timer• Improper wiring specification[Measures to Take]• Check the wiring diagram.• Check the continuity test using a multimeter.• Check the signal operation specification of the device connected.• Check the communication parame...

  • Page 461

    4293-E P-454SECTION 8 ERRORS• Reinstall the suitable control data file. 0325 Memory disk ROM access sector overEeoemale7084Reading from or writing to the memory disk (FR) is attempted exceeding the capacity of the largest sector. [Character-string]None[Code]XXXX->Sector number[Probable Fa...

  • Page 462

    4293-E P-455SECTION 8 ERRORS0330 Floppy disc read/writeEeoemale7088Read/write operation using floppy disk has not been completed correctly.[Character-string]None[Code]XXXXXXYYXXXXXX->Contents of result status 0, 1, 2, of floppy disk drive.YY:05 or 45 Error in writing 0...

  • Page 463

    4293-E P-456SECTION 8 ERRORS• Defective floppy disk or floppy disk drive• Defective main board or DMA• During execution of multi-task, contents of the main memory being accessed by another task have been changed.[Measures to Take]• Try again using another floppy disk.• Try again usin...

  • Page 464

    4293-E P-457SECTION 8 ERRORS• Defective floppy disk drive• Wrong designation of floppy disk type[Measures to Take]Avoid reformatting of floppy disks.[References]FDC Result Status (end of this book)0336 Floppy disc time outEeoemale7094The floppy disk operation completion status (service requ...

  • Page 465

    4293-E P-458SECTION 8 ERRORS[Measures to Take]Reduce the tape size.0340 PTR erratic operation detectEeoemale7098Asynchronization error with the PTR[Character-string]None[Code]PTR statusBit 1 ON->Asynchronization error[Probable Faulty Locations]• Tape roll size is too large causing a proble...

  • Page 466

    4293-E P-459SECTION 8 ERRORS• Change the FRP board. • Change the memory board. (Change the RAM card or ROM card.)[Related Specifications]DMA Error Status (at the end of this book) 0344 PrinterEeoemale7102The printer is placed in the error state, or it is not set in the ready state within a ...

  • Page 467

    4293-E P-460SECTION 8 ERRORS[Probable Faulty Locations]Defective CRP or ACP board[Measures to Take]Change the CRP or APC board.0347 Memory write/read testEeoemale7105In the read/write test of the main memory, read data and written data do not match each other.[Character-string]None[Code]Address...

  • Page 468

    4293-E P-461SECTION 8 ERRORS[Probable Faulty Locations]The file to be loaded or loading file is destroyed. [Measures to Take]• Check the content of the file to be loaded. • Check the content of the loading file. • Change the control floppy disk.0351 Program attributeEeoemale7109The pro...

  • Page 469

    4293-E P-462SECTION 8 ERRORS1-> The firmware in the FR block dose not respond.2-> The main processor has illegally accessed the buffer memory in the FR block.1XX->The FR block firmware has detected an errorXX=bit 7 to bit 3: 0(fixed)bit 2: Buffer memory errorbit 1: General-purpose regi...

  • Page 470

    4293-E P-463SECTION 8 ERRORS[Referencial Document]OSP file structure0402 Load object attributeEeoemale7116Error in load object attribute of the load object file (The data block 0 and offset 0 of the file is other than "LOB1".)[Character-string]None[Code]1[Probable Faulty Locations]•...

  • Page 471

    4293-E P-464SECTION 8 ERRORS[Probable Faulty Locations]• Floppy disk format information is other than OSP and IBM.• Record length of the floppy disk in question is 512 or 1,024 bytes.• VID or volume label information has been destroyed.[Measures to Take]• Determine forcibly using the F ...

  • Page 472

    4293-E P-465SECTION 8 ERRORS0409 File write protectEeoemale7123An attempt to release the protect state of the file which is protected by the protect command[Character-string]None[Code]Protect level[Probable Faulty Locations]• An attempt to release the protect state of the system program file...

  • Page 473

    4293-E P-466SECTION 8 ERRORSNone[Character-string]None[Code]1->An attempt to select a program2->An attempt to select a schedule program3->An attempt to execute sequence number search4->An attempt to execute restart5->An attempt to search a schedule program6->An attempt to sele...

  • Page 474

    4293-E P-467SECTION 8 ERRORS5205 Tape parityEeoemale7131Tape parity unconformity (ISO ... even parity, EIA ... odd parity)[Character-string]32 characters preceding the character which caused the parity error[Code]XX->Data which caused the parity error[Measures to Take]Because the data which ...

  • Page 475

    4293-E P-468SECTION 8 ERRORSConduct the copy operation correctly.5209 Input data overflowEeoemale7135Input data size is too large or too small.[Character-string]None[Code]Allowable maximum or minimum value for the dataFloating error statusEIOEMALE7001r01[Measures to Take]Specify the correct dat...

  • Page 476

    4293-E P-469SECTION 8 ERRORS5213 File nameEeoemale7139File name or extension name has been designated when memory condense operation was attempted.[Character-string]None[Code]None[Measures to Take]Designate the file name or extension correctly.5214 Screen buffer overflowEeoemale7140The screen b...

  • Page 477

    4293-E P-470SECTION 8 ERRORS[Character-string]None[Code]None[Measures to Take]Read the correct tape.5219 Check addressEeoemale7145Improper check address or change data setting[Character-string]None[Code]1->Address number larger than 102->No delimiter "," between the address numb...

  • Page 478

    4293-E P-471SECTION 8 ERRORS[Measures to Take]Check the main program.5223 Program buffer overflowEeoemale7149In the following operations, the program buffer becomes full while the program is being loaded.(1)Library program setting(2)Program selection(3)Schedule program selectionIn the program s...

  • Page 479

    4293-E P-472SECTION 8 ERRORSThe alarm occurs when the remaining sector size in the bubble memory is zero (0). (Code 2)This alarm means that there is no available bubble memory area in the edit buffer to output the data.[Character-string]None[Code]1->This is a warning that the bubble memory ...

  • Page 480

    4293-E P-473SECTION 8 ERRORS5232 Record buffer overflowEeoemale7158The record buffer has become full due to too many characters in one block.One block can contain up to 158 characters.[Character-string]63 characters from the beginning of the record which has caused an error[Code]1->Error has...

  • Page 481

    4293-E P-474SECTION 8 ERRORS[Code]Q data (hexadecimal) which has caused an error[Measures to Take]Input the Q data correctly.5238 'R'Eeoemale7164Character R has been specified before axis data for parameter data tape read operation.[Character-string]Block which has caused an error[Code]R numbe...

  • Page 482

    4293-E P-475SECTION 8 ERRORS[Code]FFFFFFFF->Reading through the RS232C device is impossible.[Probable Faulty Locations]Defective RS232C device or problem in wiring.5243 File attributeEeoemale7169The file is other than sequential file although A option is designated in copy operation.[Charact...

  • Page 483

    4293-E P-476SECTION 8 ERRORS5249 FMS coupling modeEeoemale7175An attempt to interrupt the robot sequence is conducted during the FMS coupling mode.- Program selection- Schedule program selection- Sequence stop- Program search- Schedule program search- Restart- PPC program selection- Cursor move...

  • Page 484

    4293-E P-477SECTION 8 ERRORSCheck the tape.5254 Machine parameterEeoemale7180An attempt to read EC specification data for the control not provided with the ECP specification while reading the parameter data.[Character-string]P number (hexadecimal) which has caused an error[Code]P number (hexade...

  • Page 485

    4293-E P-478SECTION 8 ERRORSNone[Code]1[Measures to Take]Reduce the number of sequence names used. Sequences to which jump is made using the GOTO or IF statement must beassigned with sequence names. However, other sequences may be assigned with sequence numbers.5260 Sequence nameEeoemale7186T...

  • Page 486

    4293-E P-479SECTION 8 ERRORS[Code]1[Measures to Take]• Do not register new subprograms.• Check the registered subprograms if another subprogram is called from the registered subprogram. Reduce the numberof subprograms to be within 31.5264 Library size overflowEeoemale7190An attempt to set l...

  • Page 487

    4293-E P-480SECTION 8 ERRORS5268 Nonregistered toolEeoemale7194When any of the next tool, active tool, and return tool is to be set on the ATC tool number setting screen, the designated toolnumber has not been registered in the ATC pot number/tool number correspondence table.When the next tool ...

  • Page 488

    4293-E P-481SECTION 8 ERRORS5272 Pot No. registeredEeoemale7198When an attempt to set a tool number in the pot and tool number correspondence table is made, the same tool number hasalready been set in another toolpot.[Character-string]None[Code]None[Measures to Take]• Set NONE for the pot for...

  • Page 489

    4293-E P-482SECTION 8 ERRORSNone[Code]None[Measures to Take]Designate the correct data.5278 Operand decode impossible [SPR]? [ORG]?Eeoemale7204Characters other than SPR and ORG have been entered when setting the spare tool and original tool numbers for the tool man-agement function.[Character-s...

  • Page 490

    4293-E P-483SECTION 8 ERRORS5282 Tool No. clear impossibleEeoemale7208An attempt to set "*" at the pots adjacent to the toolpot which is holding a large-diameter tool. These toolpots should have adummy tool.[Character-string]None[Code]None[Measures to Take]Abandon setting of "*&...

  • Page 491

    4293-E P-484SECTION 8 ERRORS-On the cutting condition change screen, change of F command was attempted during dry run.-On the cutting condition change screen, change of F command was attempted while F override invalidating command(M136) is in effect.-On the cutting condition change screen, chan...

  • Page 492

    4293-E P-485SECTION 8 ERRORS[Code]None5290 DNC can not transmitEeoemale7216An attempt is made to transfer an NC program in batch while DNC communication is impossible.[Character-string]None[Code]1->Attempt during communication alarm2->DNC communication off3->Not in interruption mode (D...

  • Page 493

    4293-E P-486SECTION 8 ERRORS5295 DNC transmittingEeoemale7221(DNC-B)A communication error occurred during batch transfer, resulting in abnormal termination. (DNC-C)You tried to execute an invalid command during communicating with the host computer. [Character-string](DNC-B)When a communication ...

  • Page 494

    4293-E P-487SECTION 8 ERRORSNone[Code]None5299 DNC data kindEeoemale7225In the DATA INPUT, DATA OUTPUT and DATA VERIFY operations during DNC-C mode operation, a data number which cannotbe designated is designated.[Character-string]None[Code]None5300 DNC data rangeEeoemale7226An error in the dat...

  • Page 495

    4293-E P-488SECTION 8 ERRORS[Code]None5305 Coordinate system number undefinedEeoemale7231Though a coordinate system number was undefined, it was about to carry out symbol registration.[Character-string]None[Code]None5306 Geometory definitionEeoemale7232It was about to define the symbol dimensio...

  • Page 496

    4293-E P-489SECTION 8 ERRORS5313 Not found pitch comp. data fileEeoemale7239The pitch error compensation data file is not found in the bubble memory (BB0:) when back up of this file is attempted.[Character-string]None[Code]1->No file2->Sector length of the file differs from the compensati...

  • Page 497

    4293-E P-490SECTION 8 ERRORSDesignate the correct axis name.5318 Program select impossibleEeoemale7244This alarm occurs in preparatory operation if OPERATION READY is selected with a file other than MIN used as an edited or cre-ated file.[Character-string]None[Code]None[Measures to Take]The ope...

  • Page 498

    4293-E P-491SECTION 8 ERRORS[Character-string]None[Code]None5324 No calculation resultEeoemale7250No calculation result is provided.[Character-string]None[Code]None5325 No last resultEeoemale7251When power supply is turned on, operation result is not provided. That is, no calculation result (so...

  • Page 499

    4293-E P-492SECTION 8 ERRORS[Code]None[Measures to Take]Chamfer size data must be positive.5330 2 lines parallelEeoemale7256The designated two lines are parallel to each other.This error occurs during the calculation of coordinates.[Character-string]None[Code]None[Measures to Take]Check the inp...

  • Page 500

    4293-E P-493SECTION 8 ERRORS5335 Circle inside another circleEeoemale7261When the two designated circles are compared, one circle is inside the other circle.This error occurs during the calculation of coordinates.[Character-string]None[Code]None[Measures to Take]Check the input pattern and inpu...

  • Page 501

    4293-E P-494SECTION 8 ERRORS5340 Convert codeEeoemale7266In the reverse conversion of pattern cycle, an incorrect code is found within block data.[Character-string]None[Code]None[Measures to Take]• X, Y, Z and F may be specified only once in a block.• I and K pairs for LAA and Q and K pairs...

  • Page 502

    4293-E P-495SECTION 8 ERRORS[Character-string]None[Code]None[Measures to Take]Input the data again correctly.5345 Area commandEeoemale7271Wrong data is found when confirmation drawing for the milling cycle is to be output.[Character-string]None[Code]None[Measures to Take]Check the input data.53...

  • Page 503

    4293-E P-496SECTION 8 ERRORS5349 Select numberEeoemale7275Wrong pattern number is input for the drilling cycle, hole position pattern, milling cycle, and circle cutting cycle.[Character-string]None[Code]None[Measures to Take]Check the pattern number and input a pattern number within a specified...

  • Page 504

    4293-E P-497SECTION 8 ERRORS5354 Select plane maximum return unmatchingEeoemale7280Upper limit level return operation (M52) is effective only on the XY plane.The error occurs if the upper limit level return is effective on a plane other than the XY plane or if M52 is contained in the blockdata,...

  • Page 505

    4293-E P-498SECTION 8 ERRORS5359 MSB buffer overflowEeoemale7285At the time of power supply, the program buffer for MSBs is full.[Character-string]None[Code]None[Measures to Take]Check the number of MSBs.Since the program buffer capacity is factory-set according to the MSB size stored in MD0,th...

  • Page 506

    4293-E P-499SECTION 8 ERRORSThis error occurs if a tool length offset number is designated when a tool length offset value is designated.[Measures to Take]Designate the tool length offset number after confirming the number of allowed tool length offset data sets and the data beingspecified.5363...

  • Page 507

    4293-E P-500SECTION 8 ERRORS5367 Animation data file readEeoemale7293In reading the animated data file for program selection, an error was detected in the file.[Character-string]632->Program end code633->ELETE statement634->DEF statement636->Improper value367->Illegal character63...

  • Page 508

    4293-E P-501SECTION 8 ERRORS5370 Can't block insert in DIALOGUE DATA (T-code)Eeoemale7296It instructed a tool switching instruction and an instruction except for a deflection on simultaneous in a basis operation instruction.[character string]None[code]None[Measures to Take]Please delete the too...

  • Page 509

    4293-E P-502SECTION 8 ERRORSY ->Field number0->Tool number1->Tool type2->Material code3->Tool diameter4->The number of cutting edges5->Pitch6->Nose angle7->Tool nose diameter8->Tool length offset number9->Cutter radius compensation numberZZZZZZ->Line number w...

  • Page 510

    4293-E P-503SECTION 8 ERRORS5379 Data read punch device nameEeoemale7305In the parameter input/output function, the device name is wrongly designated.[Character-string]None[Code]None[Measures to Take]Designate the correct device name.5380 Thermal deviation compensation executingEeoemale7306Ther...

  • Page 511

    4293-E P-504SECTION 8 ERRORS5385 WRONG DATA FORMATEeoemale7311During activation of NC-equipped MOP-TOOL, invalid data was entered.[Character-string]None[Code]None[Measures to Take]Re-enter the relevant data within the setting range.[Related Specifications]MOP-TOOL built in OSP7000M5386 BEYOND D...

  • Page 512

    4293-E P-505SECTION 8 ERRORS[Character-string]None[Code]None[Measures to Take]The same analog port cannot be used as input ports of different parameters. Select another analog port.When setting "load parameter" at the zero-level flag, select the "load parameter" by designati...

  • Page 513

    4293-E P-506SECTION 8 ERRORSNone[Measures to Take]Set a memory address smaller than the mounted memory address.[Related Specifications]OSP7000M built-in type MOP-TOOL5394 NO-PROGRAMED REF.Eeoemale7320On the built-in type MOP-TOOL, allowable value limit value adaptive control upper limit adaptiv...

  • Page 514

    4293-E P-507SECTION 8 ERRORS[Measures to Take]Because the built-in type MOP-TOOL is standard-equipped with a flag communication function,this alarm will not normallyoccur.Should it occur, re-create a PBU file for storing built-in type MOP-TOOL parameters.[Related Specifications]OSP7000M built-i...

  • Page 515

    4293-E P-508SECTION 8 ERRORS[Character-string]None[Code]1->The number of AP files in the program has exceeded the stack capacity of 16.[Measures to Take]Correct the program.[Related Specifications]Scroll machining function5402 AP data sizeEeoemale7328(1)The <record of positional data size...

  • Page 516

    4293-E P-509SECTION 8 ERRORSRe-set the problem data within its setting range.[Related Specifications]Scroll machining function5405 File operation executeEeoemale7331[Character-string]None[Code]None[Measures to Take][Related Specifications]Scroll machining function5406 AP file parameterEeoemale7...

  • Page 517

    4293-E P-510SECTION 8 ERRORS[Code]1->Format error2->A TPRF was entered through MDI input though the designated AP file was not loaded in the execution buffer.Other than the above->Number of AP data points (for all the axes) (in hexadecimal)[Probable Faulty Locations]Faulty program or A...

  • Page 518

    4293-E P-511SECTION 8 ERRORSReinstall.Reissue the installation floppy disk.5412 Adaptive control or Remote buffer operationEeoemale7338The operations <sequence search> or <restart> was attempted in adaptive control mode, or <sequence search> was attemptedduring remote buffer o...

  • Page 519

    4293-E P-512SECTION 8 ERRORS[Measures to Take]Review the command line.5427 DNC-DT Program selectEeoemale7346An alarm occurred during program selection by DNC-DT.[Index]None[Character-string]None[Code]XX: application error number8000000YY: communication error numberXX=6F: Small buffer size in TC...

  • Page 520

    4293-E P-513SECTION 8 ERRORS5428 Hard Disk initialEeoemale7347Initialization of the hard disk was attempted though a program being selected by DNC-DT.[Index]None[Character-string]None[Code]XXXX=6F: Small buffer size in TCP/IP driverXX=72: Faulty descriptor transferred to TCP/IP driverXX=73: Fau...

  • Page 521

    4293-E P-514SECTION 8 ERRORSXX=6F: Small buffer size in TCP/IP driverXX=72: Faulty descriptor transferred to TCP/IP driverXX=73: Faulty parameter transferred to TCP/IP driverXX=74: No empty port in the shared memoryXX=75: UnconnectedXX=7B: Abort command ignoredXX=7D: "ftp_ms_open" abn...

  • Page 522

    4293-E P-515SECTION 8 ERRORS[Code]number of a registered tool met the (teapot of number) by tool list input.2 A tool could not be arranged in layout arrangement simulation of tool arrangement simulation.3 Input of tool list file which could not arrange a tool concerning tool arrangement simul...

  • Page 523

    4293-E P-516SECTION 8 ERRORS8103 Input data overflow (PLC)Eeoemale7656The input data exceeds the allowable data input range. [Measures to Take]Set the data in the allowable input range. 8104 Invalid identifierEeoemale7657An illegal identifier name was specified. Or, an unused label was specifie...

  • Page 524

    4293-E P-517SECTION 8 ERRORS2: The identifier information 2 contains an excessive number of data pieces.[Measures to Take]Consult your nearest service center.8111 PLC Data formatEeoemale7664The file formats of PSPB*. CNS, PSPC*. CNS, and PSPD*. CNS do not agree. [Measures to Take]Consult your n...

  • Page 525

    4293-E P-518SECTION 8 ERRORSChange the tool number to be set. Or, clear the tool number already registered in the POT NO./TOOL NO. TABLE or as anactive tool to "None" before setting the tool number again.(Fixed address ATC)Change the tool number to be set. Or, clear the tool number al...

  • Page 526

    4293-E P-519SECTION 8 ERRORS8207 Registered tool none Eeoemale7676The tool specified using the tool number search function is not found in the POT NO./TOOL NO. TABLE.[Measures to Take][Probable Faulty Locations]Check if the specified tool number is correct.8208 Can not clear tool No.Eeoemale767...

  • Page 527

    4293-E P-520SECTION 8 ERRORSEnter a character string for the sequence name or the sequence number.9002 It's not the time data "H:M:S".Eeoemale7356Enter the time in the format of hour, colon, minute, colon, and second.Ex.) When setting 1 hour, 59 minutes, and 30 seconds, enter 1:59:30....

  • Page 528

    4293-E P-521SECTION 8 ERRORS9010 Can not edit - Not selected main program.Eeoemale7364Program editing was attempted by pressing [F6] (EDIT) though no main program is selected from the main program window dis-played in the automatic operation mode. Program editing by depression of [F6] (PROGRAM ...

  • Page 529

    4293-E P-522SECTION 8 ERRORS9018 Input impossible except for numerals.Eeoemale7372Parentheses of up to five nesting levels, +, -, /, * (four arithmetic operations), or +/- (signs) cannot be used to specify this param-eter.[Measures to Take]Enter a numeric value.9019 The FIND function except for...

  • Page 530

    4293-E P-523SECTION 8 ERRORS• Select the parameter setting mode, and press [F8] (DISPLAY CHANGE). Then, select NC OPTIONAL PARAMETER(LONG, WORD, BIT) from the display change window menu. The OSP can send data only when all the following param-eters are set at ON. Initially they are set at ON ...

  • Page 531

    4293-E P-524SECTION 8 ERRORS9028 RS232C OPEN.Eeoemale7381The selected RS232C channel is busy. To change the channel, select the parameter setting mode, and select NC OPTIONALPARAMETER (TAPE PUNCH INTERFECE) from the display change menu, and set a required channel number at the DEVICENAME on pag...

  • Page 532

    4293-E P-525SECTION 8 ERRORS[Code]NCOS error information (see Error No. 9028 for details.)[Measures to Take]• If the error occurs once in a long whileShorten the cable length, or use reliable an optical converter and cable.• If the error occurs frequentlyDisplay the NC OPTIONAL PARAMETER (T...

  • Page 533

    4293-E P-526SECTION 8 ERRORS9041 Can not jump!Eeoemale7388In jump operation, any of the following data was entered as the number of lines.- A number smaller than 0- A value other than the number- A number other than the integer[Character-string]Entered number of lines to be jumped[Measures to T...

  • Page 534

    4293-E P-527SECTION 8 ERRORS9050 Specified file is edited or displayed in other function.Eeoemale7397The file specified for editing is being edited or displayed by another function.9051 Can not direct edit more than 2 files at the same time.Eeoemale7398Direct editing of a file was attempted whi...

  • Page 535

    4293-E P-528SECTION 8 ERRORS- Name of file to be deleted in file deletion- File name for file protect/unprotect- New file name in renaming process- File name at VERIFY1 or VERIFY 2 in file verification process 2) Device name input field and file name input field are both blank in one-touch copy...

  • Page 536

    4293-E P-529SECTION 8 ERRORSEntered file name9064 Not a text file. Can not verify.Eeoemale7411A binary file is specified at VERIFY 1 VERIFY 2 in the verification process.[Character-string]File name at VERIFY 1 or VERIFY 2 (absolute path) 9065 It's not a sequence name or numerals.Eeoemale7412Da...

  • Page 537

    4293-E P-530SECTION 8 ERRORS9070 Can not start ONETOUCH IGF.Eeoemale74179071 A number of a letter in 1 line are over 155.Eeoemale7418The line length that can be read by the parameter input/output function or by the program operation (RS232C) is limited to 155characters. If longer than that, the...

  • Page 538

    4293-E P-531SECTION 8 ERRORSFor the remote buffer operation via DNC-RT (lathes) or DNC-DT (machining centers), any of TC:, TCA: to TCH: should beselected as a device. Select a suitable device.9076 RS232C IF not open. Can not send DC code.Eeoemale7423The OSP failed to send a DC code and caused t...

  • Page 539

    4293-E P-532SECTION 8 ERRORS9082 Sequence NO. direct.Eeoemale7685The start sequence number or an increment value is wrongly specified in the sequence number arrangement. [Code] 1-> The start sequence number or the increment value is a value larger than four-digit value.3 -> Either the st...

  • Page 540

    4293-E P-533SECTION 8 ERRORS9403 Set impossible on the multi-turn rot.table's LIMIT.Eeoemale7430As the positive and negative travel limits of the rotary table with the multi-turn specification (whether multi-turn or not can beselected by parameter setting), fixed values (-9720.0000 to 9720.0000...

  • Page 541

    4293-E P-534SECTION 8 ERRORS9410 ACT TOOL/NEXT TOOL/POT NO. exist.Eeoemale74369411 A number of comment including () in comment are over 80.Eeoemale7437Using the parameter output function, a message of up to 80 characters including () can be inserted into the program. If longerthan 80 characters...

  • Page 542

    4293-E P-535SECTION 8 ERRORS9420 Input MAC.-SCH.NO.Eeoemale7695You pressed "OK" or a function button without entering a machining order on the "MOVE" or "DATA SEARCH" window in themachining schedule edit screen for each pallet. [Measures to Take]Enter a machining o...

  • Page 543

    4293-E P-536SECTION 8 ERRORS9803 Beyond the range of identifier.Eeoemale7443The specified identifier address exceeds the processing range.The address range may be exceeded or auxiliary information may be abnormal.[Measures to Take]• Create and install a correct auxiliary information file.• ...

  • Page 544

    4293-E P-537SECTION 8 ERRORS99004 Illegal file type.Eeoemale7449An invalid file type was specified by the PLOAD or MLOAD statement in the load information file.[Probable Faulty Locations]Control software[Measures to Take]Examine the control software.99005 Illegal load address.Eeoemale7450The lo...

  • Page 545

    4293-E P-538SECTION 8 ERRORS• The mating communication board indicated by any of the above codes[Measures to Take]• Examine the control software.• Examine the startup condition of the mating communication board indicated by the codes.• Examine the board.• Reinstall the board.• Repla...

  • Page 546

    4293-E P-539SECTION 8 ERRORS99013 Too deep nest to INCLUDE.Eeoemale7458The load information file has a tool deep nesting level formed by use of INCLUDE statements.[Probable Faulty Locations]Control software[Measures to Take]Examine the control software.99014 Illegal header.Eeoemale7459The heade...

  • Page 547

    4293-E P-540SECTION 8 ERRORS99019 Initialize failed.Eeoemale7702Initialization in file loading or initialization of the window system failed. [Code]Hexadecimal number notation (aabbccdd)aa; Outline of processing1: Language change information file 2: Language combination information file3: FWS4:...

  • Page 548

    4293-E P-541SECTION 8 ERRORSl Reading data in the logical space of H80000000-FFFFFFFF in the user mode.[Code]The address that the CPU of the FWMB accessed[Probable Faulty Locations]• FWMB• Control software[Measures to Take]Replace the FWMB and see if the above error still occurs.99103 Illeg...

  • Page 549

    4293-E P-542SECTION 8 ERRORS• FWMB• Control software[Measures to Take]Replace the FWMB and see if the above error still occurs.99107 Undefined exceptionEeoemale7470The CPU of the FWMB detected an undefined exception. The undefined exceptions are: TLB mistake exception, TLB invalidexception,...

  • Page 550

    4293-E P-543SECTION 8 ERRORS[Measures to Take]Replace the FWMB and see if the above error still occurs.99201 KernelEeoemale7475The kernel operated by the FWMB detected an error.[Code]The detail of the error is described by the combination of the four numbers: type, ercd, inf1 and inf2. The typ...

  • Page 551

    4293-E P-544SECTION 8 ERRORS99203 InternalEeoemale7477An error occurred in the FWMB firmware.[Code]Internal value[Probable Faulty Locations]• FWMB• Control software[Measures to Take]Replace the FWMB and see if the above error still occurs.99204 Panel DriverEeoemale7478An abnormality occurre...

  • Page 552

    4293-E P-545SECTION 8 ERRORS99208 I/O managerEeoemale7482An abnormality occurred in the I/O manager.[Code]Internal value[Probable Faulty Locations]• FWMB• Control software[Measures to Take]Replace the FWMB and see if the above error still occurs.99209 Chardisp driverEeoemale7483An abnormali...

  • Page 553

    4293-E P-546SECTION 8 ERRORSNMI: NMI was detected.SlaveSharMemParity: A parity error occurred in the shared memory during the slave mode operation.SlaveSysBusProtect: A protect error occurred during the slave mode operation.SlaveSysBusDataParity: A data parity error occurred during the slav...

  • Page 554

    4293-E P-547SECTION 8 ERRORS99307 Program exitEeoemale7491The program ended at the FWMB.[Code]Error code and firstly finished task ID99308 No CompactFlashEeoemale7492The CompactFlash is removed from the FWMB.[Probable Faulty Locations]FWMB, CompactFlash[Measures to Take]Check the CompactFlash f...

  • Page 555

    4293-E P-548SECTION 8 ERRORS99405 argument too muchEeoemale7498The monitor command contains too many arguments.[Probable Faulty Locations]Input command[Measures to Take]Reduce the number of the arguments in the monitor command.99406 internal errorEeoemale7499Error occurred inside of the monitor...

  • Page 556

    4293-E P-549SECTION 8 ERRORSName of the code set file[Probable Faulty Locations] Control software[Measures to Take]Check the control software. 99453 CodesetFile has no languageEeoemale7705The language identifier shown by the code does not exist in the CodesetFile.[Code] Language identifier[Prob...

  • Page 557

    4293-E P-550SECTION 8 ERRORS99459 Illegal block length in font dataEeoemale7711The header of the font data is wrong. [Probable Faulty Locations]Control software or FWMB is faulty.[Measures to Take]Check the control software or replace the FWMB. 99460 Illegal bitmap boundary in font dataEeoemale...

  • Page 558

    4293-E P-551SECTION 8 ERRORSControl software99502 Resfile close more than open.Eeoemale7508The resource file has already been closed.[Probable Faulty Locations]Control software99503 Exclusive resfile.Eeoemale7509The resource file has already been opened.[Code]Project ID[Probable Faulty Location...

  • Page 559

    4293-E P-552SECTION 8 ERRORS[Code]Resource ID of the MUTEX[Probable Faulty Locations]Control software99509 MUTEX fail to lock.Eeoemale7515Lock of the MUTEX failed.[Character-string]Function name.[Code]Resource ID of the MUTEX[Probable Faulty Locations]Control software99510 MUTEX fail to unlock....

  • Page 560

    4293-E P-553SECTION 8 ERRORS[Code]Resource ID of the thread[Probable Faulty Locations]Control software99515 pipe_get: illegal packet magic.Eeoemale7521The correct magic code was not recorded in the header of data received through the pipe.[Code]Received magic code.[Probable Faulty Locations]Con...

  • Page 561

    4293-E P-554SECTION 8 ERRORS99522 efrpc_call: Unknown special packet.Eeoemale7527Unexpected special packet was returned from the server during the remote call.[Code]ID of the returned special packet[Probable Faulty Locations]• Control software• Communication procedure error.• The control ...

  • Page 562

    4293-E P-555SECTION 8 ERRORSFunction name99529 EFRPC: Channel already open.Eeoemale7534The efrpc_open or efrpc_bind function tried to reopen the remote call channel that has been already open.[Character-string]Function name[Code]Channel ID[Probable Faulty Locations]Control software99530 efrpc_b...

  • Page 563

    4293-E P-556SECTION 8 ERRORS[Probable Faulty Locations]Control software99536 efrpc_open: Can not get host info.Eeoemale7541Host name was not converted to the IP address in connection to the EBIFRY RPC channel.[Character-string]Host name to connect99537 efrpc_open: Can not open socket.Eeoemale75...

  • Page 564

    4293-E P-557SECTION 8 ERRORS99545 socket_put: Packet size too large.Eeoemale7550The packet size to be sent through the socket is too large.[Code]Packet size to be sent99546 socket_put: Header write error.Eeoemale7551Error occurred when the packet header is sent to the socket.[Code]The errno val...

  • Page 565

    4293-E P-558SECTION 8 ERRORS99555 Array subscript out of range GET.Eeoemale7559The array subscript is out of its range.[Character-string]"BYTE": Byte array."SINT": Short integer array."INT": Integer array."REAL": Real array."RESRCARRAY": Resourc...

  • Page 566

    4293-E P-559SECTION 8 ERRORS[Code]PPCCLLLL: Project ID.PP: Project ID.CC: Class ID.LLLL: Local ID.[Probable Faulty Locations]Control software99560 Illegal local ID.Eeoemale7564The specified resource ID includes an invalid local ID.[Character-string]Function name[Code]Resource ID[Probable Faulty...

  • Page 567

    4293-E P-560SECTION 8 ERRORS99565 Lack of resource table entry.Eeoemale7569Free area has run short in the resource table entry.[Character-string]Function name[Code]Project ID[Probable Faulty Locations]Control software99566 Fail to get virtual memory.Eeoemale7570Preserving the virtual memory spa...

  • Page 568

    4293-E P-561SECTION 8 ERRORSProject ID[Probable Faulty Locations]Control software99572 Too large resource.Eeoemale7575The size of the resource of create is too large.[Character-string]Function name[Code]Project ID[Probable Faulty Locations]Control software99573 Corrupt external resource file.Ee...

  • Page 569

    4293-E P-562SECTION 8 ERRORS99579 Old EBIFRY format resource fileEeoemale7580An invalid resource file was specified.[Character-string]Function name.[Code]Project ID[Probable Faulty Locations]Control software99580 Unrecognized format resource file.Eeoemale7581An invalid resource file was specifi...

  • Page 570

    4293-E P-563SECTION 8 ERRORSControl software99585 resrc_ref_count: Unavailable resource.Eeoemale7586Unavailable resource was specified.[Code]Resource ID[Probable Faulty Locations]Control software99586 resrc_change_size: No more memory.Eeoemale7587Resource size change failed due to not enough me...

  • Page 571

    4293-E P-564SECTION 8 ERRORS99595 No trap exception.Eeoemale7593The exception process routine was not found.After dumping out the EBIFRY stack to the console area, the system causing the address exception can be stopped by startingthe process from 0xbad00bad address.[Probable Faulty Locations]C...

  • Page 572

    4293-E P-565SECTION 8 ERRORSEnd the direct editing, make more free space by deleting unnecessary files, and then start the editing.99605 File operation failed. (block seek)Eeoemale7599Updating the file pointer failed during direct editing of a file or listing a large file.[Character-string]Name...

  • Page 573

    4293-E P-566SECTION 8 ERRORSPrinter device name to open99614 Fail to open printer.Eeoemale7608Failure to open the printer[Character-string]Printer device name.99615 Invalid printer filter specified.Eeoemale7609Invalid printer filter was specified.[Character-string]Printer device name[Code]Code ...

  • Page 574

    4293-E P-567SECTION 8 ERRORS99640 Invalid format for initialize.Eeoemale7616The specified format is not applicable.[Character-string]Device name99650 Invalid file for protect.Eeoemale7617The specified file is provided with a high protection level like a system program, and cannot be an object o...

  • Page 575

    4293-E P-568SECTION 8 ERRORS99656 Invalid file name.Eeoemale7623An invalid file name (device name) was specified.[Character-string]File name (device name) that caused this error[Probable Faulty Locations]• File or directory name spelling is incorrect.• The specified file or device name is n...

  • Page 576

    4293-E P-569SECTION 8 ERRORS99662 Device full.Eeoemale7629There is not enough free area to create files and directories.[Character-string]File name (directory name) that caused this error[Measures to Take]• Delete unnecessary files.• Initialize the device.99663 Different devices.Eeoemale763...

  • Page 577

    4293-E P-570SECTION 8 ERRORS[Character-string]File name (directory name) that caused this error[Probable Faulty Locations]Directory name spelling is incorrect.[Measures to Take]• Empty the directory.• Specify the correct directory name.99668 Can not remove root directory.Eeoemale7635Deletin...

  • Page 578

    4293-E P-571SECTION 8 ERRORSThe same file is edited or listed simultaneously by more than one file operation.99704 Now copying or deleting in other function.Eeoemale7640The same file is being copied or deleted by another file operation. (On the contrary, the file cannot be copied or deleted wh...

  • Page 579

    4293-E P-572SECTION 8 ERRORS99784 File name mismatch.Eeoemale7646The name of file being edited does not agree with the name of file to be saved in the direct editing mode.[Character-string]File name under the direct editing mode[Probable Faulty Locations]Control software99785 Illegal recorder f...

  • Page 580

    4293-E P-573SECTION 8 ERRORSSequence number (hexadecimal) to be assigned [Probable Faulty Locations] • There are too many sequence numbers to be assigned.• The increment value of the sequence number is too large. [Measures to Take] Specify the sequence start number and incremental value by...

  • Page 581

    4293-E P-574SECTION 9 APPENDIXSECTION 9 APPENDIX1.Factor Classification Code/Factor ParameterEeoemalap001Factor Classification Code (XX)Factor Parameter (YY)03......]04......EOR06......OR08......AND0A......NOT00000000000C.......Relative operation01...... LT 02...... LE 03...... EQ04...... NE 05...

  • Page 582

    4293-E P-575SECTION 9 APPENDIX2.FDC Result StatusEeoemalap002Result Status 0 (ST0)NT : Normal terminate, AT : Abnormal Terminate,IC : Invalid Command, AI : Attention InterruptReasult Status 1 (ST1)Bit No.Status NameAbbreviationContentsD7InterruptCodeICIndicates the cause of generating INT reque...

  • Page 583

    4293-E P-576SECTION 9 APPENDIXNoteResult Status 2 (ST2)NoteD1Not WritableNWThe bit data is set when the write?disable condition is detected during execution of the WRITE DATA, WRITE DELETED DATA and WRITE ID commands.D0MissingAddressMarkMA(1) The bit data is set when the AM (Address Mark) is n...

  • Page 584

    4293-E P-577SECTION 9 APPENDIXResult Status 3 (ST3)Bit No.Status NameAbbreviationContentsD7FaultFTStatus of Fault signal from the deviceD6WriteProtectedWPStatus of Write Protect signal from the deviceD5ReadyRYStatus of Ready signal from the deviceD4Track 0T0Status of Track 0 signal from the de...

  • Page 585

    4293-E P-578SECTION 9 APPENDIX3.DMA Error StatusEeoemalap003DMA Error Status (Memory Disk)Bit No.Status NameContents15S/D1When the DMA accessed the source address, an error occurred.0When the DMA accessed the destination address, an error occurred.140Fixed to 0.13COE1Count errorWhen TC [Transfe...

  • Page 586

    4293-E P-579SECTION 9 APPENDIX3PORTERR1Port size errorWhen the DMA became a bus master and accessed the system bus, the slave’s port size was 16 bits/8 bits.0No error2CYOERR1Cycle over errorWhen the DMA became a bus master and accessed the system bus, a cycle over error occurred. (Detection t...

  • Page 587

    4293-E P-580SECTION 9 APPENDIXDMA Error Status (Floppy Disk)Bit No.Status NameContents15COE1Count errorAlthough "0" was set at MTC (DMA control bit 14 to 0), "1" was written at STR.0No error14ADE1Address errorThe DMA became a bus master and accessed the address space on the ...

  • Page 588

    LIST OF PUBLICATIONSPublication No.DateEdition4293-EJanuary 20002nd4293-E-R1August 20003rd4293-E-R2October 20004thThis manual may be at variance with the actual product due to specification or design changes.Please also note that pecifications are subject to change without notice.If you requirecl...

x